Fracture resistance of monolithic zirconia molar crowns with reduced thickness
(Journal article; Tidsskriftartikkel; Peer reviewed, 2015-01-30)
Objectives. The purpose of the present study was to analyze the relationship between
fracture load of monolithic zirconia crowns and axial/occlusal thickness, and to evaluate
the fracture resistance of monolithic zirconia crowns with reduced thickness in
comparison with that of monolithic lithium disilicate crowns with regular thickness.
Materials and methods. Monolithic zirconia crowns (Lava ...