dc.description.abstract<p><i>Objectives - </i>To evaluate a modified Global Trigger Tool (GTT) method with manual review of automatic triggered records to measure adverse events. <p><i>Design - </i>A cross-sectional study was performed using the original GTT method as gold standard compared to a modified GTT method. <p><i>Setting - </i>Medium size hospital trust in Northern Norway. <p><i>Participants - </i>One thousand two hundred thirty-three records selected between March and December 2013. <p><i>Main outcome measure - </i>Records with triggers, adverse events and number of adverse events identified. Recall (sensitivity), precision (positive predictive value), specificity and Cohen’s kappa with 95 % confidence interval were calculated. <p><i>Results - </i>Both methods identified 35 adverse events per 1000 patient days. The modified GTT method with manual review of 658 automatic triggered records identified adverse events (<i>n</i> = 214) in 189 records and the original GTT method identified adverse events (<i>n</i> = 216) in 186 records. One hundred and ten identical records were identified with adverse events by both methods. Recall, precision, specificity and reliability for records identified with adverse events were respectively 0.59, 0.58, 0.92 and 0.51 for the modified GTT method. The total manual review time in the modified GTT method was 23 h while the manual review time using the original GTT method was 411 h. <p><i>Conclusions - </i>The modified GTT method is as good as the original GTT method that complies with the GTTs aim monitoring the rate of adverse events. Resources saved by using the modified GTT method enable for increasing the sample size. The automatic trigger identification system may be developed to assess triggers in real-time to mitigate risk of adverse events.en_US
dc.description.sponsorshipNorthern Norway Regional Health Authorityen_US
dc.descriptionThis is a pre-copyedited, author-produced version of an article accepted for publication in the >i>International Journal for Quality in Health Care</i> following peer review. The version of record Mevik, K., Hansen, T.E., Deilkås, E.C., Ringdal, A.M. & Vonen, B. (2018). Is a modified Global Trigger Tool method using automatic trigger identification valid when measuring adverse events? A comparison of review methods using automatic and manual trigger identification. <i>International Journal for Quality in Health Care</i>, mzy210, is available online at: <a href=https://academic.oup.com/intqhc/advance-article/doi/10.1093/intqhc/mzy210/5123532>https://academic.oup.com/intqhc/advance-article/doi/10.1093/intqhc/mzy210/5123532</a>.en_US
dc.identifier.citationMevik, K., Hansen, T.E., Deilkås, E.C., Ringdal, A.M. & Vonen, B. (2018). Is a modified Global Trigger Tool method using automatic trigger identification valid when measuring adverse events? A comparison of review methods using automatic and manual trigger identification. <i>International Journal for Quality in Health Care</i>, mzy210. https://doi.org/10.1093/intqhc/mzy210en_US
dc.identifier.cristinIDFRIDAID 1654546
dc.identifier.doi10.1093/intqhc/mzy210
dc.identifier.issn1353-4505
dc.identifier.issn1464-3677
dc.identifier.urihttps://hdl.handle.net/10037/15255
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.relation.ispartofMevik, K. (2019). Identifying and measuring patient harms. A study of measuring adverse events in hospitalised patients by the Global Trigger Tool record review method. (Doctoral thesis). <a href=https://hdl.handle.net/10037/15257>https://hdl.handle.net/10037/15257</a>
dc.relation.journalInternational Journal for Quality in Health Care
dc.rights.accessRightsopenAccessen_US
dc.subjectVDP::Medical disciplines: 700::Health sciences: 800::Health service and health administration research: 806en_US
dc.subjectVDP::Medisinske Fag: 700::Helsefag: 800::Helsetjeneste- og helseadministrasjonsforskning: 806en_US
dc.subjectGlobal Trigger Toolen_US
dc.subjectAutomatic trigger identificationen_US
dc.subjectAdverse eventsen_US
dc.subjectRecord reviewen_US
dc.subjectHospital careen_US
dc.titleIs a modified Global Trigger Tool method using automatic trigger identification valid when measuring adverse events? A comparison of review methods using automatic and manual trigger identificationen_US