dc.description.abstractThe water sorption and solubility of two polymer resin‐based dental composite materials were assessed in order to evaluate the effects of immediate post‐cure water exposure on the water sensitivity of the composites. Each material was tested with two different light curing setups. The radiant exposure of the two curing setups differed by a factor of 5. After exposure to water and subsequent drying, the Knoop surface hardness was measured. The change in the degree of conversion in both water and air storage medium within the first 24 h after curing was monitored by Raman spectroscopy. No significant differences in the degree of conversion were detected 24 h after curing. Samples exposed to the lower irradiation dose showed higher solubility and a lower surface hardness than the samples exposed to the higher irradiation dose. Early exposure to water did not cause detectable differences in the ongoing polymerization process. Increase in radiant exposure reduced the fraction of unbound constituents and increased the crosslink density, thereby reducing the plasticity of the material.en_US
dc.identifier.citationWikant A, Ørtengren UT, Hakeberg M, Gedde UW. Suboptimal light curing and direct exposure to water of two contemporary composites: degree of conversion, sorption, solubility, and Knoop hardness. Acta Odontologica Scandinavica. 2020;128(4):345-353en_US
dc.identifier.cristinIDFRIDAID 1849722
dc.identifier.doi10.1111/eos.12705
dc.identifier.issn0001-6357
dc.identifier.issn1502-3850
dc.identifier.urihttps://hdl.handle.net/10037/20115
dc.language.isoengen_US
dc.publisherWileyen_US
dc.relation.ispartofWikant, A. (2023). Dental composites - The effects of matrix composition, suboptimal light curing and water exposure. (Doctoral thesis). <a href=https://hdl.handle.net/10037/28771>https://hdl.handle.net/10037/28771</a>.
dc.relation.journalActa Odontologica Scandinavica
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2020 The Author(s)en_US
dc.subjectVDP::Medical disciplines: 700::Clinical dentistry disciplines: 830en_US
dc.subjectVDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830en_US
dc.titleSuboptimal light curing and direct exposure to water of two contemporary composites: degree of conversion, sorption, solubility, and Knoop hardnessen_US