Vis enkel innførsel

dc.contributor.authorLarsen, Marthe
dc.contributor.authorAglen, Camilla Flåt
dc.contributor.authorLee, Christoph I.
dc.contributor.authorHoff, Solveig Roth
dc.contributor.authorLund-Hanssen, Håkon
dc.contributor.authorLång, Kristina
dc.contributor.authorNygård, Jan Franz
dc.contributor.authorUrsin, Giske
dc.contributor.authorHofvind, Solveig Sand-Hanssen
dc.date.accessioned2023-03-13T12:23:16Z
dc.date.available2023-03-13T12:23:16Z
dc.date.issued2022-03-29
dc.description.abstractBackground - Artificial intelligence (AI) has shown promising results for cancer detection with mammographic screening. However, evidence related to the use of AI in real screening settings remain sparse.<p> <p>Purpose - To compare the performance of a commercially available AI system with routine, independent double reading with consensus as performed in a population-based screening program. Furthermore, the histopathologic characteristics of tumors with different AI scores were explored.<p> <p>Materials and Methods - In this retrospective study, 122 969 screening examinations from 47 877 women performed at four screening units in BreastScreen Norway from October 2009 to December 2018 were included. The data set included 752 screen-detected cancers (6.1 per 1000 examinations) and 205 interval cancers (1.7 per 1000 examinations). Each examination had an AI score between 1 and 10, where 1 indicated low risk of breast cancer and 10 indicated high risk. Threshold 1, threshold 2, and threshold 3 were used to assess the performance of the AI system as a binary decision tool (selected vs not selected). Threshold 1 was set at an AI score of 10, threshold 2 was set to yield a selection rate similar to the consensus rate (8.8%), and threshold 3 was set to yield a selection rate similar to an average individual radiologist (5.8%). Descriptive statistics were used to summarize screening outcomes.<p> <p>Results - A total of 653 of 752 screen-detected cancers (86.8%) and 92 of 205 interval cancers (44.9%) were given a score of 10 by the AI system (threshold 1). Using threshold 3, 80.1% of the screen-detected cancers (602 of 752) and 30.7% of the interval cancers (63 of 205) were selected. Screen-detected cancer with AI scores not selected using the thresholds had favorable histopathologic characteristics compared to those selected; opposite results were observed for interval cancer.<p> <p>Conclusion - The proportion of screen-detected cancers not selected by the artificial intelligence (AI) system at the three evaluated thresholds was less than 20%. The overall performance of the AI system was promising according to cancer detection.en_US
dc.identifier.citationLarsen, Aglen, Lee, Hoff, Lund-Hanssen, Lång, Nygård, Ursin, Hofvind. Artificial Intelligence Evaluation of 122969 Mammography Examinations from a Population-based Screening Program. Radiology. 2022;303(3):502-511en_US
dc.identifier.cristinIDFRIDAID 2071770
dc.identifier.doi10.1148/radiol.212381
dc.identifier.issn0033-8419
dc.identifier.issn1527-1315
dc.identifier.urihttps://hdl.handle.net/10037/28725
dc.language.isoengen_US
dc.publisherRadiological Society of North Americaen_US
dc.relation.journalRadiology
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2022 The Author(s)en_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0en_US
dc.rightsAttribution 4.0 International (CC BY 4.0)en_US
dc.titleArtificial Intelligence Evaluation of 122969 Mammography Examinations from a Population-based Screening Programen_US
dc.type.versionacceptedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution 4.0 International (CC BY 4.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution 4.0 International (CC BY 4.0)