Show simple item record

dc.contributor.advisorÖrtengren, Ulf Thore
dc.contributor.authorEgenæs-Svendsen, Kristin
dc.contributor.authorEikill, Borghild Oftedal
dc.contributor.authorBjørkum, Audhild
dc.date.accessioned2015-04-17T14:10:43Z
dc.date.available2015-04-17T14:10:43Z
dc.date.issued2014-06-04
dc.description.abstractObjective: Composite resin based materials (CRM) are widely used in dentistry for its aesthetics and ability to preserve tooth structure. The main ingredients are monomers that during polymerization undergo crosslinking to form the resin matrix, bonding the material together. However, not all the monomers will react during polymerization, and remain in the matrix as free residual compounds that can elute. This is of clinical importance as monomers and their degradation products are known to cause allergic reactions, and there are concerns regarding the potential toxic effects of these eluted compounds. The objective of this study was to investigate how different ratios of bis-GMA versus bis-EMA relative to each other would influence the leakage of TEGDMA from the composite. Materials and methods: Storage solutions of experimental composites with known concentrations of bis-EMA, bis- GMA, TEGDMA and UDMA were used, with storage time 24 h, 7 days and 30 days. Three randomly collected solution samples from each group (n=36) and time interval was chosen. The analysis was performed by using GC-MS. Results: TEGDMA was detected in all samples. The results showed a trend where the group containing the most bis-EMA eluted less than the groups containing bis-GMA at the time intervals studied. Conclusions: Within the limitations of the present study the following conclusions were drawn: A trend was shown toward less leakage from the composite containing the most bis-EMA compared with the composites containing bis-GMA at the time intervals studied. The null hypothesis was therefore considered as rejected. Leakage of TEGDMA was found for all composites tested, however the quantification was uncertain. More research on the subject is needed to determine if there is a significant difference.en_US
dc.identifier.urihttps://hdl.handle.net/10037/7628
dc.identifier.urnURN:NBN:no-uit_munin_7215
dc.language.isoengen_US
dc.publisherUiT Norges arktiske universiteten_US
dc.publisherUiT The Arctic University of Norwayen_US
dc.rights.accessRightsopenAccess
dc.rights.holderCopyright 2014 The Author(s)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0en_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)en_US
dc.subject.courseIDODO-3901en_US
dc.subjectOdontologien_US
dc.subjectBiomaterialeren_US
dc.subjectVDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830en_US
dc.subjectVDP::Medical disciplines: 700::Clinical dentistry disciplines: 830en_US
dc.titleThe influence of bis-EMA content on the leachability of dental composite resinsen_US
dc.typeMaster thesisen_US
dc.typeMastergradsoppgaveen_US


File(s) in this item

Thumbnail
Thumbnail

This item appears in the following collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)