dc.description.abstractNon steady state thermal conductivity of ABS was estimated using an analytical approach in a Cold Climate Chamber at ?10?C and ?14?C. Two hollow cylinders of ABS of varying thickness were used to estimate the conductivity. The material was porous but the porosity was unknown. This paper is a case study to understand, if it is reasonable to estimate the thermal conductivity using the analytical varying thickness approach.en_US
dc.description.sponsorshipThe work reported in this research paper was carried out by Atmospheric Icing Research Team at Industrial Engineering Department of Narvik University College and was funded by Research Council of Norway, project no. 195153 (ColdTech RT3 and RT5) and Norwegian Centre for International Cooperation in Education, project number - HNP -2014/10023en_US
dc.descriptionOpen Access (Romeo Green journal), publishers version / PDF may be used <a href=http://www.scirp.org/journal/wjet/>http://www.scirp.org/journal/wjet/</a>en_US
dc.identifier.citationMughal , U.N., Makarova, M ., Virk, M .S. and Polanco , G. (2015) A Case Study to Estimate Thermal Conductivity of ABS in Cold Climate Chamber . World Journal of Engineering and Technology , 3 , 309 -315en_US
dc.identifier.cristinIDFRIDAID 1319472
dc.identifier.doi10.4236/wjet.2015.33C046
dc.identifier.issn0975-4024
dc.identifier.issn2319-8613
dc.identifier.urihttps://hdl.handle.net/10037/11855
dc.language.isoengen_US
dc.publisherScientific Research Publishing Incen_US
dc.relation.journalInternational Journal of Engineering and Technology (Chennai)
dc.relation.projectIDSiU, Senter for internasjonalisering av utdanning: HNP-2014/10023en_US
dc.relation.projectIDNorges forskningsråd: 195153en_US
dc.relation.projectIDInterreg: Wind CoE - Interreg IVA Botnia-Atlanticaen_US
dc.rights.accessRightsopenAccessen_US
dc.subjectVDP::Technology: 500en_US
dc.subjectVDP::Technology: 500::Environmental engineering: 610en_US
dc.titleA case study to estimate thermal conductivity of ABS in Cold Climate Chamberen_US
dc.typeJournal articleen_US