Performance and Design Study of Optimized LNG Mixed Fluid Cascade Processes

Permanent link
https://hdl.handle.net/10037/16399
DOI
https://doi.org/10.1016/j.energy.2019.116207
Thumbnail
View/Open
article.pdf (2.614Mb)
Accepted manuscript version (PDF)
Date
2019-09-26
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Brodal, Eivind; Jackson, Steven; Eiksund, Oddmar
Abstract
Mixed Fluid Cascade (MFC) processes are often claimed to be one of the most efficient methods to liquefy natural gas. Their performance depends on both operating conditions such as ambient temperature, and system design parameters such as exchanger sizes. The performance of the standard MFC process can be further improved by modifying the design with additional equipment, such as liquid refrigerant expanders or additional pressure levels in the refrigerant cycles. This article presents a performance study of several modified MFC processes. Results are obtained using multivariable optimization algorithms in MATLAB and a process model developed in HYSYS. Constraints related to minimum internal temperature approach are used to model the main heat exchangers. The results illustrate the impact of ambient temperature on performance, and that modifications with either two-stage pre-cooling systems or liquid expanders reduce the power consumption by 3.0%–4.5%, translating into a 15%–30% reduction in the combined UA values of the main heat exchangers.
Description
Accepted manuscript. Final version published in Energy, 189, 116207, is available at https://doi.org/10.1016/j.energy.2019.116207.
Publisher
Elsevier
Citation
Brodal, E., Jackson, S. & Eiksund, O. (2019). Performance and Design Study of Optimized LNG Mixed Fluid Cascade Processes. Energy, 189, 116207. https://doi.org/10.1016/j.energy.2019.116207
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (automasjon og prosessteknologi) [172]

Browse

Browse all of MuninCommunities & CollectionsAuthor listTitlesBy Issue DateBrowse this CollectionAuthor listTitlesBy Issue Date
Login

Statistics

View Usage Statistics
UiT

Munin is powered by DSpace

UiT The Arctic University of Norway
The University Library
uit.no/ub - munin@ub.uit.no

Accessibility statement (Norwegian only)