Quantitative analysis methods for studying fenestrations in liver sinusoidal endothelial cells. A comparative study
Permanent link
https://hdl.handle.net/10037/23019Date
2021-07-28Type
Journal articleTidsskriftartikkel
Peer reviewed
Author
Szafranska, K.; Holte, Christopher Florian; Kruse, L.D.; Mao, Hong; Øie, Cristina Ionica; Szymonski, M.; Zapotoczny, B.; McCourt, P.A.G.Abstract
Liver Sinusoidal Endothelial Cells (LSEC) line the hepatic vasculature providing blood filtration via transmembrane nanopores called fenestrations. These structures are 50−300 nm in diameter, which is below the resolution limit of a conventional light microscopy. To date, there is no standardized method of fenestration image analysis. With this study, we provide and compare three different approaches: manual measurements, a semi-automatic (threshold-based) method, and an automatic method based on user-friendly open source machine learning software. Images were obtained using three super resolution techniques – atomic force microscopy (AFM), scanning electron microscopy (SEM), and structured illumination microscopy (SIM). Parameters describing fenestrations such as diameter, area, roundness, frequency, and porosity were measured. Finally, we studied the user bias by comparison of the data obtained by five different users applying provided analysis methods.
Publisher
ElsevierCitation
Szafranska, Holte, Kruse, Mao, Øie, Szymonski, Zapotoczny, McCourt. Quantitative analysis methods for studying fenestrations in liver sinusoidal endothelial cells. A comparative study. Micron. 2021;150Metadata
Show full item recordCollections
Copyright 2021 The Author(s)