Optimization of a mixed refrigerant based H2 liquefaction pre-cooling process and estimate of liquefaction performance with varying ambient temperature

Permanent link
https://hdl.handle.net/10037/23104
DOI
https://doi.org/10.3390/en14196090
Thumbnail
View/Open
article.pdf (7.071Mb)
Published version (PDF)
Date
2021-09-24
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Jackson, Steven; Brodal, Eivind
Abstract
Hydrogen used as an energy carrier can provide an important route to the decarbonization of energy supplies, but realizing this opportunity will require both significantly increased production and transportation capacity. One route to increased transportation capacity is the shipping of liquid hydrogen, but this requires an energy-intensive liquefaction step. Recent study work has shown that the energy required in this process can be reduced through the implementation of new and improved process designs, but since all low-temperature processes are affected by the available heat-sink temperature, local ambient conditions will also have an impact. The objective of this work is to identify how the energy consumption associated with hydrogen liquefaction varies with heat-sink temperature through the optimization of design parameters for a next-generation mixed refrigerant based hydrogen liquefaction process. The results show that energy consumption increases by around 20% across the cooling temperature range 5 to 50 °C. Considering just the range 20 to 30 °C, there is a 5% increase, illustrating the significant impact ambient temperature can have on energy consumption. The implications of this work are that the modelling of different liquified hydrogen based energy supply chains should take the impact of ambient temperature into account.
Is part of
Jackson, S. (2021). The Impact of Ambient Temperature on Low Carbon Energy Supply - Modelling and optimization studies on the supply of hydrogen energy from northern Norway. (Doctoral thesis). https://hdl.handle.net/10037/23115.
Publisher
MDPI
Citation
Jackson, Brodal. Optimization of a mixed refrigerant based h2 liquefaction pre-cooling process and estimate of liquefaction performance with varying ambient temperature. Energies. 2021;14(19)
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (automasjon og prosessteknologi) [172]
Copyright 2021 The Author(s)

Browse

Browse all of MuninCommunities & CollectionsAuthor listTitlesBy Issue DateBrowse this CollectionAuthor listTitlesBy Issue Date
Login

Statistics

View Usage Statistics
UiT

Munin is powered by DSpace

UiT The Arctic University of Norway
The University Library
uit.no/ub - munin@ub.uit.no

Accessibility statement (Norwegian only)