Unbalanced low coherence interference microscopy

Permanent lenke
https://hdl.handle.net/10037/26469
DOI
https://doi.org/10.1016/j.optlaseng.2021.106932
Thumbnail
Åpne
article.pdf (3.623Mb)
Publisert versjon (PDF)
Dato
2022-01-03
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Ahmad, Azeem; Habib, Anowarul; Dubey, Vishesh Kumar; Ahluwalia, Balpreet Singh
Sammendrag
Low coherence interference microscopy (LCIM) provides high spatial phase sensitivity, i.e., speckle free and coherent noise free quantitative phase images of the test specimens. Due to low temporal coherence (TC) length of the light source, LCIM requires precise adjustment of the optical path difference (OPD) between the object and the reference arm, which is only a few micrometers. Consequently, previously demonstrated LCIM systems are implemented with the use of identical objective lenses in both the arms and also known as balanced interferometric configuration. The use of identical objective lens hinders both the use of high numerical aperture objective lens and also the swift change of the objective lens during imaging. In the present work, LCIM is implemented with non-identical objective lenses in the object and the reference arm also called unbalanced optical configuration. A range of objective lenses 10 × /0.25NA, 20 × /0.45NA and 60 × /1.2NA are employed in the object arm of the system while keeping single objective lens 10 × /0.25NA in the reference arm. To resolve the challenges associated with unbalanced configuration, advanced iterative algorithm (AIA) and principal component analysis (PCA) algorithms are integrated to recover quadratic phase error free phase images of the test specimens. The capabilities of the proposed method are exhibited on various specimens like USAF resolution, step-like test object and for the biological cells, HeLa cells. The proposed approach enables scalable magnification and resolution by simply rotating the imaging objective turret without the need of changing objective lens in the reference arm.
Forlag
Elsevier
Sitering
Ahmad, Habib, Dubey, Ahluwalia. Unbalanced low coherence interference microscopy. Optics and lasers in engineering. 2022
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (fysikk og teknologi) [1057]
Copyright 2021 The Author(s)

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring