JavaScript is disabled for your browser. Some features of this site may not work without it.

Single-shot quantitative differential phase contrast microscope using a single calcite beam displacer

Permanent link
https://hdl.handle.net/10037/36724
DOI
https://doi.org/10.1364/AO.536593
Thumbnail
View/Open
article.pdf (1.054Mb)
Accepted manuscript version (PDF)
Date
2024-11-06
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Saxena, Anuj; Ahmad, Azeem; Dubey, Vishesh Kumar; Mao, Hong; Kumar, Anand; Habib, Anowarul; Dubey, Satish Kumar; Ahluwalia, Balpreet Singh; Mehta, Dalip Singh
Abstract
This paper presents the development of a single-shot, partially spatially coherent quantitative differential phase contrast microscopy (Q-DPCM) system. The optical scheme comprises a polarizer, lenses, calcite beam displacer, and analyzer, which can be seamlessly integrated to an existing bright-field microscopy system, transforming it into a Q-DPCM system. It utilizes a partially spatially coherent light source, enabling single-shot quantitative differential phase recovery of the specimens with high spatial phase sensitivity. It generates highly sensitive quantitative differential phase images of the specimens along one direction, like a gradient light interference microscopy (GLIM) system, using only a single interferogram. First, we validated the differential phase measurement capability of the system through experiments on polystyrene spheres (diameter 5.2 µm) and HeLa cells. Next, the system is utilized to generate quantitative phase maps of human red blood cells using two orthogonal differential interferograms recorded at two orientations of the calcite beam displacer. Further, the Q-DPCM system is implemented for 1-h time-lapse live cell monitoring, revealing the dynamics of intracellular granules such as nucleolus and lipids in U2OS cells.
Publisher
Optica Publishing Group
Citation
Saxena, Ahmad, Dubey, Mao, Kumar, Habib, Dubey, Ahluwalia, Mehta. Single-shot quantitative differential phase contrast microscope using a single calcite beam displacer. Applied Optics. 2024;63(32):8350-8358
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (fysikk og teknologi) [1057]
Copyright 2024 The Author(s)