Addressing Cross-Coupling Issues in Magnetically Integrated Three-Port DC-DC Converters

Permanent lenke
https://hdl.handle.net/10037/37167
DOI
https://doi.org/10.1109/PEMC61721.2024.10726373
Thumbnail
Åpne
article.pdf (829.7Kb)
Innsendt manusversjon (PDF)
Dato
2024-10-25
Type
Conference object
Konferansebidrag

Forfatter
Carvalho, Edivan Laercio; Blinov, Andrei; Sohail, Umer; Chub, Andrii
Sammendrag
DC grid-forming converters are used to provide dc power distribution inside buildings. Often, such converters are based on dual-active bridge (DAB) technology to provide high-frequency isolation. Certain developing standards related to dc installations specify different isolation classes and protection zones. This is a critical requirement for power converter design, especially for building applications where end-users are close to the loads, and it is necessary to provide extra safety. To comply with these requirements, isolation is needed between the primary DC buses (700 Vdc), dc power distribution buses (320-380 Vdc), and extra-low voltage levels (24-60 Vdc), where loads are connected. Three-port converters are a potential solution for this application to reduce the number of power processing stages. However, when working under droop control at the output, magnetic cross-coupling issues must be addressed. In this paper, a three-port isolated dc-dc converter is described and analyzed, verifying the influence of magnetic cross-coupling on the extra-low voltage port, which is usually not regulated. To experimentally verify this proposal, a 5.3 kW prototype was built, and laboratory tested, comparing different transformer designs.
Forlag
IEEE
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (elektroteknologi) [131]
Copyright 2024 The Author(s)

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring