dc.description.abstractReduction of data centre power consumption is a timely challenge. Waste heat reuse is another focus area when developing energy efficient and sustainable data centres. And these two issues are interconnected through liquid cooling of server racks and/or direct-to-chip liquid cooling. Both of these solutions make it possible to transfer a significant proportion of the waste heat energy back to profitable use. Nevertheless, the heat reusing opportunity is not the only benefit direct-to-chip liquid cooling may offer. Another benefit is the notable reduction of power consumption related to cooling fans associated with server blades and rack-level cooling systems. To evaluate this benefit, we performed power consumption and performance measurements in a subarctic supercomputer centre hosting a cluster of 632 blade nodes. Our study concentrated on a 47-node subset that we analysed when the servers were executing the LINPACK benchmark. Our conclusion is that direct-to-chip liquid cooling can reduce the total power consumption, in this case, up to 14.4% depending on the inlet air temperature.en_US
dc.descriptionPublisher's pdf. Source at <a href=http://doi.org/10.1504/IJHPCN.2016.076269>http://doi.org/10.1504/IJHPCN.2016.076269</a>en_US
dc.identifier.citationOvaska, SJ; Dragseth, RE; Hanssen, SA: Direct-to-chip liquid cooling for reducing power consumption in a subarctic supercomputer centre. International Journal of High Performance Computing and Networking. 2016;9(3):242-249en_US
dc.identifier.cristinIDFRIDAID 1384502
dc.identifier.doi10.1504/IJHPCN.2016.076269
dc.identifier.issn1740-0562
dc.identifier.issn1740-0570
dc.identifier.urihttps://hdl.handle.net/10037/10887
dc.language.isoengen_US
dc.publisherInderscienceen_US
dc.relation.journalInternational Journal of High Performance Computing and Networking
dc.rights.accessRightsopenAccessen_US
dc.subjectVDP::Teknologi: 500::Informasjons- og kommunikasjonsteknologi: 550::Datateknologi: 551en_US
dc.subjectVDP::Technology: 500::Information and communication technology: 550::Computer technology: 551en_US
dc.subjectdata centreen_US
dc.subjectdirect-to-chip liquid coolingen_US
dc.subjectpower consumptionen_US
dc.subjectsubarctic climateen_US
dc.subjectsupercomputeren_US
dc.subjectwaste heat reuseen_US
dc.titleDirect-to-chip liquid cooling for reducing power consumption in a subarctic supercomputer centreen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel