Vis enkel innførsel

dc.contributor.authorPham, Le Nam Hai
dc.contributor.authorWagle, Raju
dc.contributor.authorGonzalez-Longatt, Francisco
dc.date.accessioned2023-04-05T09:03:34Z
dc.date.available2023-04-05T09:03:34Z
dc.date.issued2023-03-28
dc.description.abstractIn the significant widespread transition towards clean energies, there has been an unstoppable trend in integrating renewable energy sources (RSs) in distribution networks. However, the massive penetration of integrated multisources into conventional distribution systems may create several operational problems, such as malfunctioning protection systems. This paper concisely defines the setting for overcurrent protection applied to the CIGRE European (EU) Medium Voltage (MV) benchmark network. The benchmark system is commonly recommended for RSs penetration studies. In this paper, the authors show the calculations and results of the nondirectional and directional overcurrent protection relay in a very educational and detailed way. The definition of the settings considers several operating situations and two short-circuit (SC) types: three-phase and single-line-to-ground. The main contribution of this paper is a well-documented and validated overcurrent protection settings of the CIGR EU MV that can be used for teaching and research purposes.en_US
dc.identifier.citationPham LNH, Wagle R, Gonzalez-Longatt F: Concise Definition of the Overcurrent Protection System for CIGRE European Medium Voltage Benchmark Network. In: Harid. 2023 IEEE PES Conference on Innovative Smart Grid Technologies - Middle East (ISGT Middle East), 2023. IEEE conference proceedingsen_US
dc.identifier.cristinIDFRIDAID 2138668
dc.identifier.doi10.1109/ISGTMiddleEast56437.2023.10078621
dc.identifier.isbn978-1-6654-6543-4
dc.identifier.urihttps://hdl.handle.net/10037/28939
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2023 The Author(s)en_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0en_US
dc.rightsAttribution 4.0 International (CC BY 4.0)en_US
dc.titleConcise Definition of the Overcurrent Protection System for CIGRE European Medium Voltage Benchmark Networken_US
dc.type.versionacceptedVersionen_US
dc.typeChapteren_US
dc.typeBokkapittelen_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution 4.0 International (CC BY 4.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution 4.0 International (CC BY 4.0)