Vis enkel innførsel

dc.contributor.authorWunderlich, Lucia
dc.contributor.authorStröhl, Florian
dc.contributor.authorStröhl, Stefan
dc.contributor.authorVanderpoorten, Oliver
dc.contributor.authorMascheroni, Luca
dc.contributor.authorKaminski, Clemens F.
dc.date.accessioned2020-12-07T08:49:10Z
dc.date.available2020-12-07T08:49:10Z
dc.date.issued2020-12-05
dc.description.abstractImmunofluorescence microscopy is routinely used in the diagnosis of and research on renal impairments. However, this highly specific technique is restricted in its maximum resolution to about 250 nm in the lateral and 700 nm in the axial directions and thus not sufficient to investigate the fine subcellular structure of the kidney’s glomerular filtration barrier. In contrast, electron microscopy offers high resolution, but this comes at the cost of poor preservation of immunogenic epitopes and antibody penetration alongside a low throughput. Many of these drawbacks were overcome with the advent of super-resolution microscopy methods. So far, four different super-resolution approaches have been used to study the kidney: single molecule localization microscopy (SMLM), stimulated emission depletion (STED) microscopy, structured illumination microscopy (SIM), and expansion microscopy (ExM), however using different preservation methods and widely varying labelling strategies. In this work, all four methods were applied and critically compared on kidney slices obtained from samples treated with the most commonly used preservation technique: fixation by formalin and embedding in paraffin (FFPE). Strengths and weaknesses, as well as the practicalities of each method are discussed to enable users of super-resolution microscopy in renal research make an informed decision on the best choice of technique. The methods discussed enable the efficient investigation of biopsies stored in kidney banks around the world.en_US
dc.identifier.citationWunderlich L, Ströhl F, Ströhl, Vanderpoorten O, Mascheroni L, Kaminski CF. Superresolving the kidney – a practical comparison of fluorescence nanoscopy of the glomerular filtration barrier. Analytical and Bioanalytical Chemistry. 2020en_US
dc.identifier.cristinIDFRIDAID 1851439
dc.identifier.doi10.1007/s00216-020-03084-8
dc.identifier.issn1618-2642
dc.identifier.issn1618-2650
dc.identifier.urihttps://hdl.handle.net/10037/19997
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.journalAnalytical and Bioanalytical Chemistry
dc.relation.projectIDERC-European Research Council: 836355en_US
dc.relation.projectIDEC/H2020: 836355en_US
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/MitoQuant/836355/Norway/Development of Deep-UV Quantitative Microscopy for the Study of Mitochondrial Dysfunction//en_US
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2020 The Author(s)en_US
dc.subjectVDP::Mathematics and natural science: 400::Physics: 430en_US
dc.subjectVDP::Matematikk og Naturvitenskap: 400::Fysikk: 430en_US
dc.titleSuperresolving the kidney – a practical comparison of fluorescence nanoscopy of the glomerular filtration barrieren_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel