Vis enkel innførsel

dc.contributor.authorBrodal, Eivind
dc.contributor.authorEiksund, Oddmar
dc.date.accessioned2021-03-08T10:15:24Z
dc.date.available2021-03-08T10:15:24Z
dc.date.issued2019-11-19
dc.description.abstractThis article investigates tap water heating systems to highlight an ongoing debate. Some report that CO2-based transcritical heat pumps with an ejector have the best coefficient of performance (COP), while others report that blend-based refrigerant systems (without an ejector) are better. In the literature, however, these systems are only compared with conventional heat pump designs, and not against each other, making it difficult to conclude which design is the best. In addition, the outcome of combining the two modifications has not been explored extensively. This article investigates the performance of heat pumps using mixtures of CO2 and propane, with and without an ejector or a suction gas heat exchanger. It presents a novel method for modeling blend-based heat pumps with an ejector using an optimization approach and a minimum allowed temperature pinch in heat exchangers. A sensitivity study explores how the heat pump performance depends on operating conditions, ejector efficiency and the refrigerant blend. The sensitivity studies allow for the comparison of the heat pump designs. For example, the results show that it is inefficient to use CO2 and propane blends in systems with an ejector. A blend-based system with a suction gas heat exchanger was found to outperform a CO2-based system with an ejector if either the tap water is above 25 °C, the ejector efficiency is below 0.17, or the temperature of the heat source is reduced with more than 10 K when flowing through the evaporator.en_US
dc.identifier.citationBrodal E, Eiksund O. Optimization study of heat pumps using refrigerant blends – Ejector versus expansion valve systems. International journal of refrigeration. 2020;111en_US
dc.identifier.cristinIDFRIDAID 1767268
dc.identifier.doi10.1016/j.ijrefrig.2019.11.015
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.urihttps://hdl.handle.net/10037/20649
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.journalInternational journal of refrigeration
dc.relation.urihttps://munin.uit.no/handle/10037/16884
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2020 The Author(s)en_US
dc.subjectVDP::Technology: 500::Building technology: 530::Hydrotechnology: 538en_US
dc.subjectVDP::Teknologi: 500::Bygningsfag: 530::Hydroteknologi: 538en_US
dc.titleOptimization study of heat pumps using refrigerant blends – Ejector versus expansion valve systemsen_US
dc.type.versionacceptedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US