Vis enkel innførsel

dc.contributor.authorAganovic, Amar
dc.contributor.authorCao, Guangyu
dc.contributor.authorFečer, Tomáš
dc.contributor.authorLjungqvist, Bengt L.
dc.contributor.authorLytsy, Birgitta
dc.contributor.authorRadtke, Andreas
dc.contributor.authorReinmüller, Berit
dc.contributor.authorTraversari, Roberto A.A.L.
dc.date.accessioned2021-10-21T08:23:49Z
dc.date.available2021-10-21T08:23:49Z
dc.date.issued2021-04-26
dc.description.abstractWithout confirmation of the ventilation design conditions (typology and airflow rate), the common practice of identifying unidirectional airflow (UDAF) systems as equivalent to ultra-clean air ventilation systems may be misleading, but also any claims about the ineffectiveness of UDAF systems should be doubted. The aim of this review was to assess and compare ventilation system design conditions for which ultra-clean air (mean <10 cfu/m<sup>3</sup>) within 50 cm from the wound has been reported. Six medical databases were systematically searched to identify and select studies reporting intraoperative airborne levels expressed as cfu/m<sup>3</sup> close to the wound site, and ventilation system design conditions. Available data on confounding factors such as the number of persons present in the operating room, number of door openings, and clothing material were also included. Predictors for achieving mean airborne bacteria levels within <10 cfu/m<sup>3</sup> were identified using a penalized multivariate logistic regression model. Twelve studies met the eligibility criteria and were included for analysis. UDAF systems considered had significantly higher air volume flows compared with turbulent ventilation (TV) systems considered. Ultra-clean environments were reported in all UDAF-ventilated (<i>N</i> = 7) rooms compared with four of 11 operating rooms equipped with TV. On multivariate analysis, the total number of air exchange rates (<i>P</i>=0.019; odds ratio (OR) 95% confidence interval (CI): 0.66–0.96) and type of clothing material (<i>P</i>=0.031; OR 95% CI: 0.01–0.71) were significantly associated with achieving mean levels of airborne bacteria <10 cfu/m<sup>3</sup>. High-volume UDAF systems complying with DIN 1946-4:2008 standards for the airflow rate and ceiling diffuser size unconditionally achieve ultra-clean air close to the wound site. In conclusion, the studied articles demonstrate that high-volume UDAF systems perform as ultra-clean air systems and are superior to TV systems in reducing airborne bacteria levels close to the wound site.en_US
dc.identifier.citationAganovic, Cao, Fečer, Ljungqvist, Lytsy, Radtke, Reinmüller, Traversari. Ventilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic review. Journal of Hospital Infection. 2021;113:85-95en_US
dc.identifier.cristinIDFRIDAID 1916924
dc.identifier.doi10.1016/j.jhin.2021.04.022
dc.identifier.issn0195-6701
dc.identifier.issn1532-2939
dc.identifier.urihttps://hdl.handle.net/10037/22803
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.journalJournal of Hospital Infection
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2021 The Author(s)en_US
dc.subjectVDP::Medical disciplines: 700en_US
dc.subjectVDP::Medisinske Fag: 700en_US
dc.subjectVDP::Technology: 500en_US
dc.subjectVDP::Teknologi: 500en_US
dc.titleVentilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic reviewen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel