Vis enkel innførsel

dc.contributor.authorLu, Jinmei
dc.contributor.authorLeiviska, Tiina
dc.contributor.authorWalder, Ingar
dc.date.accessioned2021-11-04T12:49:34Z
dc.date.available2021-11-04T12:49:34Z
dc.date.issued2021-05-28
dc.description.abstractDry covers can be applied above tailings to reduce and prevent formation of acid mine drainage and leaching of contaminants. Efficiency of covers is affected by different parameters, of which temperature change under climate change context is one. Here, a laboratory column leaching experiment was performed under four temperatures, 5, 10, 14, and 18 °C on unoxidized tailings from Ballangen, Norway. 600 mL of water was added to each column every second week and leachate was collected and analyzed for pH, salinity, alkalinity, concentrations of sulfate, Co, Fe, Mn, Ni, and Zn. A thin layer of digested sewage sludge was added to columns after the 16th leaching cycle. In total, 21 leaching cycles were performed. Results showed low oxidation of tailings and therefore high pH and low salinity, SO42−, Fe, Ni, and Co in the leachates at leaching temperature of 5 °C. Addition of sludge cover slowed down oxidation of underlying tailings and decreased leaching of SO42−, Fe, Mn, Co, Ni, and Zn from the tailings deposit, especially at relatively high temperatures. 10 °C is a threshold temperature, below which leaching is not affected by the cover addition so much. At a leaching temperature higher than 10 °C, the sludge cover addition can reduce the leaching of elements significantly.en_US
dc.identifier.citationLu J, Leiviska T, Walder. The effect of temperature and digested sewage sludge cover over tailings on the leaching of contaminants from Ballangen tailings deposit. Journal of Water and Climate Change. 2021en_US
dc.identifier.cristinIDFRIDAID 1924974
dc.identifier.doi10.2166/wcc.2021.068
dc.identifier.issn2040-2244
dc.identifier.urihttps://hdl.handle.net/10037/22932
dc.language.isoengen_US
dc.publisherIWAen_US
dc.relation.journalJournal of Water and Climate Change
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2021 The Author(s)en_US
dc.subjectVDP::Technology: 500::Environmental engineering: 610en_US
dc.subjectVDP::Teknologi: 500::Miljøteknologi: 610en_US
dc.titleThe effect of temperature and digested sewage sludge cover over tailings on the leaching of contaminants from Ballangen tailings depositen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel