dc.description.abstractLung cancer is currently the first leading cause of worldwide cancer deaths since the early stage of lung cancer detection is still a challenge. In lung diagnosis, nodules sometimes overlap with ribs and tissues on lung chest radiographic images, which are complex for doctors and radiologists. Dual-energy subtraction (DES) is a suitable solution to solve those issues. This article will develop an efficient iterative DES for lung chest radiographic images. Moreover, we propose an automatic algorithm for accurately determining bone and soft-tissue factors for subtraction. The proposed algorithm for determining the bone and soft-tissue factors is based on window/level ratio and radiographic histogram analysis. First, we take the image sampling from the original size 3072 × 3072 to 512 × 512 to reduce the processing time while achieving the bone and soft-tissue factors. Next, we compute the window/level ratio on the soft-tissue image. Finally, we determine the minimum value of the ratio to obtain the optimal soft-tissue and bone factors. Our experimental results show that our proposed algorithm achieves a minimized runtime of 200 ms, outperforming the GE algorithm’s time of 4 s. The runtime of our DES of 6.066 s is shorter than the Fujifilm algorithm of 10 s while visualizing nodules on soft-tissue images and obtaining a similar quality of the soft-tissue images compared with the other algorithms. The academic contributions include the proposed algorithm for determining bone and soft-tissue factors and the optimized iterative DES algorithm to minimize time and dose consumption.en_US
dc.identifier.citationDo Q, Seo, Shin. Automatic algorithm for determining bone and soft-tissue factors in dual-energy subtraction chest radiography. Biomedical Signal Processing and Control. 2022;80(2):1-10en_US
dc.identifier.cristinIDFRIDAID 2072718
dc.identifier.doihttps://doi.org/10.1016/j.bspc.2022.104354
dc.identifier.issn1746-8094
dc.identifier.issn1746-8108
dc.identifier.urihttps://hdl.handle.net/10037/27560
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.journalBiomedical Signal Processing and Control
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2022 The Author(s)en_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0en_US
dc.rightsAttribution 4.0 International (CC BY 4.0)en_US
dc.subjectVDP::Medisinske fag: 700::Klinisk medisinske fag: 750::Lungesykdommer: 777en_US
dc.subjectVDP::Midical sciences: 700::Clinical medical sciences: 750::Lung diseases: 777en_US
dc.titleAutomatic algorithm for determining bone and soft-tissue factors in dual-energy subtraction chest radiographyen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution 4.0 International (CC BY 4.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution 4.0 International (CC BY 4.0)