JavaScript is disabled for your browser. Some features of this site may not work without it.

Security Constrained Unit Commitment and Economic Dispatch by AC Sensitivity Factors

Permanent link
https://hdl.handle.net/10037/28822
DOI
https://doi.org/10.1109/ARGENCON55245.2022.9939863
Thumbnail
View/Open
article.pdf (537.6Kb)
Accepted manuscript version (PDF)
Date
2022-11-09
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Tricarico, Gioacchino; Wagle, Raju; Azuara-Grande, Luis Santiago; Gonzalez-Longatt, Francisco; Dicorato, Maria; Forte, Giuseppe; Rueda, Jose Luis
Abstract
The dispatch schedule of the electrical power plant units is the result of the solution to the unit commitment optimisation problem, and it minimises the cost of production considering pre-defined technical limits. The security-constrained unit commitment problem has been defined as including the network constraints in the previously mentioned optimisation problem to obtain a feasible power system solution. The traditional security-constrained unit commitment methods are based on the DC-power flow model, where the network losses and voltage magnitudes are neglected in the problem formulation. This paper proposed a bi-stage security-constrained unit commitment with an economic dispatch (SCUCED) optimisation problem. A merit-order-based zonal day-ahead market problem is solved in the first stage to define a preliminary generation commitment. In the second stage, the SCUCED is solved based on the AC-power flow model and sensitivity factors to embed the full network representation in the optimisation problem. In this paper, the proposed method is illustrated by an application to a modified version of the IEEE 39-bus test system.
Publisher
IEEE
Citation
Tricarico G, Wagle R, Azuara-Grande LS, Gonzalez-Longatt FGL, Dicorato M, Forte G, Rueda JL: Security Constrained Unit Commitment and Economic Dispatch by AC Sensitivity Factors. In: IEEE .. 2022 IEEE VI Congreso Bienal de Argentina ARGENCON: SAN JUAN, ARGENTINA 07-09 SEPTEMBER 2022, 2022. IEEE conference proceedings
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (elektroteknologi) [127]
Copyright 2022 The Author(s)