Vis enkel innførsel

dc.contributor.advisorJacobsen, Svein
dc.contributor.authorTobiassen, Alexander
dc.date.accessioned2011-02-21T12:50:06Z
dc.date.available2011-02-21T12:50:06Z
dc.date.issued2010-10-27
dc.description.abstractBreast cancer is one of the most frequent types of cancer in the female population today. Modern diagnostic modalities, while proven to be helpful within large scale screening programs, are inherently limited with regards to specificity and sensitivity, and use active methods for acquisition of information. A passive and non-invasive method for detection and diagnostic purposes could therefore be a valuable asset to the existing technology. One such method is microwave radiometry. A microwave radiometer is an instrument for non-invasive thermography of subcutaneous temperatures. Recent advances within the field has demonstrated that this technology could be helpful in conjunction with existing methods. This thesis presents the design, implementation and experimental verification of a miniaturized medical microwave radiometer. The design is based on the Switch-Circulator Dicke-configuration to minimize effects of gain variations and mismatch at the antenna input. The performance of the radiometric system is verified through phantom experiments with a hot object embedded at various depths in a homogeneous, lossy medium. Results display a good coherence with regards to linearity, temperature sensitivity and repeatability. For an integration time constant of 2s, the temperature resolution is found to be approximately 0.07C, which is comparable with similar instruments as reported in literature.en
dc.identifier.urihttps://hdl.handle.net/10037/2958
dc.identifier.urnURN:NBN:no-uit_munin_2689
dc.language.isoengen
dc.publisherUniversitetet i Tromsøen
dc.publisherUniversity of Tromsøen
dc.rights.accessRightsopenAccess
dc.rights.holderCopyright 2010 The Author(s)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0en_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)en_US
dc.subject.courseIDFYS-3921en
dc.subjectVDP::Mathematics and natural science: 400::Physics: 430::Electronics: 435en
dc.subjectVDP::Matematikk og Naturvitenskap: 400::Fysikk: 430::Elektronikk: 435en
dc.subjectVDP::Technology: 500::Medical technology: 620en
dc.subjectVDP::Teknologi: 500::Medisinsk teknologi: 620en
dc.subjectMicrowave Radiometryen
dc.subjectMikrobølgeradiometrien
dc.subjectBreast Canceren
dc.subjectBrystkreften
dc.titleImproved hardware stability and signal amplification in a medical microwave radiometeren
dc.typeMaster thesisen
dc.typeMastergradsoppgaveen


Tilhørende fil(er)

Thumbnail
Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution-NonCommercial-ShareAlike 3.0 Unported (CC BY-NC-SA 3.0)