Vis enkel innførsel

dc.contributor.authorAhmad, Azeem
dc.contributor.authorGoclowski, Pawel Piotr
dc.contributor.authorDubey, Vishesh Kumar
dc.contributor.authorTrusiak, Maciej
dc.contributor.authorAhluwalia, Balpreet Singh
dc.date.accessioned2024-09-17T07:57:38Z
dc.date.available2024-09-17T07:57:38Z
dc.date.issued2024-04-22
dc.description.abstractCurrent low coherence quantitative phase microscopy (LC-QPM) systems suffer from either reduced field of view (FoV) or reduced temporal resolution due to the short temporal coherence (TC) length of the light source. Here, we propose a hybrid, experimental and numerical approach to address this core problem associated with LC-QPM. We demonstrate high spatial resolution and high phase sensitivity in LC-QPM at high temporal resolution. High space–time bandwidth product is achieved by employing incoherent light source for sample illumination in QPM to increase the spatial resolution and single-shot Hilbert spiral transform (HST) based phase recovery algorithm to enhance the temporal resolution without sacrificing spatial resolution during the reconstruction steps. The high spatial phase sensitivity comes by default due to the use of incoherent light source in QPM which has low temporal coherence length and does not generate speckle noise and coherent noise. The spatial resolution achieved by the HST is slightly inferior to the temporal phase-shifting (TPS) method when tested on a specimen but surpasses that of the single-shot Fourier transform (FT) based phase recovery method. Contrary to HST method, FT method requires high density fringes for lossless phase recovery, which is difficult to achieve in LC-QPM over entire FoV. Consequently, integration of HST algorithm with LC-QPM system makes an attractive route. Here, we demonstrate scalable FoV and resolution in single-shot LC-QPM and experimentally corroborate it on a test object and on both live and fixed biological specimen such as MEF, U2OS and human red blood cells (RBCs). LC-QPM system with HST reconstruction offer high-speed single-shot QPM imaging at high phase sensitivity and high spatial resolution enabling us to study sub-cellular dynamic inside U2OS for extended duration (3 h) and observe high-speed (50 fps) dynamics of human RBCs. The experimental results validate the effectiveness of the present approach and will open new avenues in the domain of biomedical imaging in the future.en_US
dc.identifier.citationAhmad, Goclowski, Dubey, Trusiak, Ahluwalia. High space–time bandwidth product imaging in low coherence quantitative phase microscopy. Scientific Reports. 2024;14(1)en_US
dc.identifier.cristinIDFRIDAID 2267184
dc.identifier.doi10.1038/s41598-024-59874-y
dc.identifier.issn2045-2322
dc.identifier.urihttps://hdl.handle.net/10037/34745
dc.language.isoengen_US
dc.publisherSpringer Natureen_US
dc.relation.journalScientific Reports
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2024 The Author(s)en_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0en_US
dc.rightsAttribution 4.0 International (CC BY 4.0)en_US
dc.titleHigh space–time bandwidth product imaging in low coherence quantitative phase microscopyen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution 4.0 International (CC BY 4.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution 4.0 International (CC BY 4.0)