Vis enkel innførsel

dc.contributor.authorBerstad, Audun Elnæs
dc.contributor.authorBrabrand, Knut
dc.contributor.authorHorneland, Rune
dc.contributor.authorSyversveen, Trygve
dc.contributor.authorHaugaa, Håkon
dc.contributor.authorJenssen, Trond Geir
dc.contributor.authorFoss, Aksel
dc.date.accessioned2020-02-14T13:14:52Z
dc.date.available2020-02-14T13:14:52Z
dc.date.issued2019-02-12
dc.description.abstract<i>Background</i> - Arterial and venous thrombosis are feared complications of pancreas transplantation (PTx). Microbubble contrast-enhanced ultrasound (CEUS) is a non-invasive imaging technique that can augment diagnostic capabilities of transplant organ perfusion.<p><p> <i>Purpose</i> - To document the state to which CEUS can improve the vascular evaluation of PTx compared to conventional Doppler ultrasound (US) directly after surgery.<p><p> <i>Material and Methods</i> - A total of 129 consecutive PTx in 128 adult patients were eligible for inclusion. The duodenal segment of the graft was anastomosed to the native duodenum. Within 12 h postoperatively, graft circulation was monitored by Doppler US in 116 PTx performed in 116 patients (69 men, 47 women; mean age =41 years). CEUS was performed with a sulfur hexafluoride-containing contrast agent (SonoVue) intravenously if the examiner was not able to confirm normal graft circulation. Image quality was documented by two independent observers on a 4-point scale: 1 = excellent; 2 = minor diagnostic limitations; 3 = major diagnostic limitations; and 4 = non-diagnostic.<p><p> <i>Results</i> - In the early postoperative phase, 79 (68%) of 116 PTx were examined with Doppler US only. Of these, 52 were of excellent quality (grade 1), 22 of good quality (grade 2), and five were of grade 3 or 4 quality. Thirty-seven (32%) examinations were supplemented by CEUS. CEUS significantly improved examination quality compared to Doppler US alone (median visualization score 1.5 vs. 2.5, respectively; <i>P</i> < 0.0001).<p><p> <i>Conclusion</i> - CEUS can significantly improve vascular evaluation of PTx compared to Doppler US alone in the early postoperative phase.en_US
dc.identifier.citationBerstad AE, Braband K, Horneland R, Syversveen T, Haugaa H, Jenssen TG, Foss A. Microbubble contrast-enhanced ultrasound in the vascular evaluation after pancreas transplantation: a single-center experience. Acta Radiologica. 2019:1-8en_US
dc.identifier.cristinIDFRIDAID 1704037
dc.identifier.doi10.1177/0284185119828190
dc.identifier.issn0284-1851
dc.identifier.issn1600-0455
dc.identifier.urihttps://hdl.handle.net/10037/17397
dc.language.isoengen_US
dc.publisherSAGE Publicationsen_US
dc.relation.journalActa Radiologica
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright © 2019, © SAGE Publicationsen_US
dc.subjectVDP::Medical disciplines: 700en_US
dc.subjectVDP::Medisinske Fag: 700en_US
dc.titleMicrobubble contrast-enhanced ultrasound in the vascular evaluation after pancreas transplantation: a single-center experienceen_US
dc.type.versionacceptedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel