Vis enkel innførsel

dc.contributor.authorUsmani, Kashif
dc.contributor.authorAhmad, Azeem
dc.contributor.authorJoshi, Rakesh
dc.contributor.authorDubey, Vishesh Kumar
dc.contributor.authorButola, Ankit
dc.contributor.authorMehta, Dalip Singh
dc.date.accessioned2020-02-24T13:17:59Z
dc.date.available2020-02-24T13:17:59Z
dc.date.issued2019-11-25
dc.description.abstractCoherence properties of light sources are indispensable for optical coherence microscopy/tomography as they greatly influence the signal-to-noise ratio, axial resolution, and penetration depth of the system. In the present paper, we report the investigation of longitudinal spatial coherence properties of a pseudothermal light source (PTS) as a function of the laser spot size at the rotating diffuser plate. The laser spot size is varied by translating a microscope objective lens toward or away from the diffuser plate. The longitudinal spatial coherence length, which governs the axial resolution of the coherence microscope, is found to be minimum for the beam spot size of 3.5 mm at the diffuser plate. The axial resolution of the system is found to be equal to an ∼13µm at 3.5 mm beam spot size. The change in the axial resolution of the system is confirmed by performing the experiments on standard gauge blocks of a height difference of 15 µm by varying the spot size at the diffuser plate. Thus, by appropriately choosing the beam spot size at the diffuser plane, any monochromatic laser light source can be utilized to obtain high axial resolution irrespective of the source’s temporal coherence length. It can provide speckle-free tomographic images of multilayered biological specimens with large penetration depth. In addition, a PTS avoids the use of any chromatic-aberration-corrected optics and dispersion-compensation mechanism unlike conventional setups.en_US
dc.identifier.citationUsmani, Ahmad A, Joshi, Dubey VK, Butola A, Mehta DS. Relationship between the source size at the diffuser plane and the longitudinal spatial coherence function of the optical coherence microscopy system. Optical Society of America. Journal A: Optics, Image Science, and Vision. 2019;36(12):D41-D46en_US
dc.identifier.cristinIDFRIDAID 1776846
dc.identifier.doi10.1364/JOSAA.36.000D41
dc.identifier.issn1084-7529
dc.identifier.issn1520-8532
dc.identifier.urihttps://hdl.handle.net/10037/17459
dc.language.isoengen_US
dc.publisherOptical Society of Americaen_US
dc.relation.journalOptical Society of America. Journal A: Optics, Image Science, and Vision
dc.rights.accessRightsopenAccessen_US
dc.rights.holder© 2019 Optical Society of Americaen_US
dc.subjectVDP::Mathematics and natural science: 400en_US
dc.subjectVDP::Matematikk og Naturvitenskap: 400en_US
dc.titleRelationship between the source size at the diffuser plane and the longitudinal spatial coherence function of the optical coherence microscopy systemen_US
dc.type.versionacceptedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel