Vis enkel innførsel

dc.contributor.authorStarck, Lea
dc.contributor.authorAndersen, Erling
dc.contributor.authorMacíček, Ondřej
dc.contributor.authorAngenete, Oskar W
dc.contributor.authorAugdal, Thomas Angell
dc.contributor.authorRosendahl, Karen
dc.contributor.authorJirík, Radovan
dc.contributor.authorGrüner, Renate
dc.date.accessioned2021-06-21T20:43:10Z
dc.date.available2021-06-21T20:43:10Z
dc.date.issued2021-01-13
dc.description.abstractThe temporomandibular joint (TMJ) is typically involved in 45–87% of children with Juvenile Idiopathic Arthritis (JIA). Accurate diagnosis of JIA is difficult as various clinical tests, including MRI, disagree. The purpose of this study is to optimize the methodological aspects of Dynamic Contrast Enhanced (DCE) MRI of the TMJ in children. In this cross-sectional study, including data from 73 JIA affected children, aged 6–15 years, effects of motion correction, sampling rate and parametric modelling on DCE-MRI data is investigated. Consensus among three radiologists determined the regions of interest. Quantitative perfusion parameters were estimated using four perfusion models; the Adiabatic Approximation to Tissue Homogeneity (AATH), Distributed Capillary Adiabatic Tissue Homogeneity (DCATH), Gamma Capillary Transit Time (GCTT) and Two Compartment Exchange (2CXM) models. Effects of motion correction were evaluated by a sum of least squares between corrected raw data and the GCTT model. The effect of systematically down sampling the raw data was tested. The sum of least squares was computed across all pharmacokinetic models. Relative difference perfusion parameters between the left and right TMJ were used for an unsupervised k-means based stratification of the data based on a principal component analysis, as well as for a supervised random forest classification. Diagnostic sensitivity and specificity were computed relative to structural image scorings. Paired sample t-tests, as well as ANOVA tests, were used (significant threshold: p < 0.05) with Tukeys post hoc test. High-level elastic motion correction provides the best least square fit to the GCTT model (percental improvement: 72–84%). A 4 s sampling rate captures more of the potentially disease relevant signal variations. The various parametric models all leave comparable residues (relative standard deviation: 3.4%). In further evaluation of DCE-MRI as a potential diagnostic tool for JIA a high-level elastic motion correction scheme should be adopted, with a sampling rate of at least 4 s. Results suggest that DCE-MRI data can be a valuable part in JIA diagnostics in the TMJ.en_US
dc.identifier.citationStarck, Andersen, Macíček, Angenete, Augdal, Rosendahl, Jirík, Grüner. Effects of motion correction, sampling rate and parametric modelling in dynamic contrast enhanced MRI of the temporomandibular joint in children affected with juvenile idiopathic arthritis. Magnetic Resonance Imaging. 2021;77:204-212en_US
dc.identifier.cristinIDFRIDAID 1871115
dc.identifier.doi10.1016/j.mri.2020.12.014
dc.identifier.issn0730-725X
dc.identifier.issn1873-5894
dc.identifier.urihttps://hdl.handle.net/10037/21498
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.journalMagnetic Resonance Imaging
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2021 The Author(s)en_US
dc.subjectVDP::Technology: 500::Medical technology: 620en_US
dc.subjectVDP::Teknologi: 500::Medisinsk teknologi: 620en_US
dc.titleEffects of motion correction, sampling rate and parametric modelling in dynamic contrast enhanced MRI of the temporomandibular joint in children affected with juvenile idiopathic arthritisen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel