A novel algorithm to detect non-wear time from raw accelerometer data using deep convolutional neural networks

Permanent link
https://hdl.handle.net/10037/21607
DOI
https://doi.org/10.1038/s41598-021-87757-z
Thumbnail
View/Open
article.pdf (1.928Mb)
Published version (PDF)
Date
2021-04-23
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Syed, Shaheen; Morseth, Bente; Hopstock, Laila Arnesdatter; Horsch, Alexander
Abstract
To date, non-wear detection algorithms commonly employ a 30, 60, or even 90 mins interval or window in which acceleration values need to be below a threshold value. A major drawback of such intervals is that they need to be long enough to prevent false positives (type I errors), while short enough to prevent false negatives (type II errors), which limits detecting both short and longer episodes of non-wear time. In this paper, we propose a novel non-wear detection algorithm that eliminates the need for an interval. Rather than inspecting acceleration within intervals, we explore acceleration right before and right after an episode of non-wear time. We trained a deep convolutional neural network that was able to infer non-wear time by detecting when the accelerometer was removed and when it was placed back on again. We evaluate our algorithm against several baseline and existing non-wear algorithms, and our algorithm achieves a perfect precision, a recall of 0.9962, and an F1 score of 0.9981, outperforming all evaluated algorithms. Although our algorithm was developed using patterns learned from a hip-worn accelerometer, we propose algorithmic steps that can easily be applied to a wrist-worn accelerometer and a retrained classification model.
Publisher
Springer
Citation
Syed, Morseth, Hopstock, Horsch. A novel algorithm to detect non-wear time from raw accelerometer data using deep convolutional neural networks. Scientific Reports. 2021;11(1):1-12
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (informatikk) [484]
Copyright 2021 The Author(s)

Browse

Browse all of MuninCommunities & CollectionsAuthor listTitlesBy Issue DateBrowse this CollectionAuthor listTitlesBy Issue Date
Login

Statistics

View Usage Statistics
UiT

Munin is powered by DSpace

UiT The Arctic University of Norway
The University Library
uit.no/ub - munin@ub.uit.no

Accessibility statement (Norwegian only)