Vis enkel innførsel

dc.contributor.authorMo, Arild
dc.contributor.authorHjortsjö, Carl
dc.contributor.authorJokstad, Asbjørn
dc.date.accessioned2022-12-02T12:24:30Z
dc.date.available2022-12-02T12:24:30Z
dc.date.issued2022-08-27
dc.description.abstractBackground: Clinical data are needed on long-term outcomes of removable implantsupported prostheses in the fully edentulous maxilla as a function of the number of implants, effects of the attachment system and other clinical variables.<p> <p>Objective: To restore individuals with an edentate maxilla with a metal-reinforced removable prosthesis without palatal coverage retained by low-profile stud attachments on three implants. <p>Methods: The regional ethics committee approved a prospective cohort study that included all consecutive patients treated in a private speciality clinic. Primary outcomes were patients reported, that is denture satisfaction scale and oral health-related quality of life – OHIP-20. Secondary outcomes were implant- (bone loss, implant complications and peri-implant conditions) and prosthesis-related (prosthesis complications, maintenance needs and mucosa condition). <p>Results: Thirty-two study participants were recruited between March 2007 and October 2016 and followed for a minimum of five years. According to Kruskal–Wallis tests, the OHIP-20 and Denture Satisfaction Scale questionnaire pre-treatment scores differed significantly. After an average of 6.7 years, peri-implant bone loss of more than 2 mm was observed on 17% of all implants, while no or minor bone loss was seen on 38%. The estimated success of implants was 0.95 at 168 months. The estimated success of the prosthesis, that is no adverse events or need for any repairs, was 0.55 at 156 months. <p>Conclusion: The positive findings in the current clinical study strengthen the notion that for many individuals with an edentulous maxilla, a removable prosthesis retained by three implants fitted with low-profile stud-attachment is a reliable technical solution.en_US
dc.identifier.citationMo A, Hjortsjö C, Jokstad A. Maxillary overdenture on three implants retained by low-profile stud attachments – A prospective cohort study. Journal of Oral Rehabilitation. 2022;49(11):1069-1079en_US
dc.identifier.cristinIDFRIDAID 2047158
dc.identifier.doi10.1111/joor.13364
dc.identifier.issn0305-182X
dc.identifier.issn1365-2842
dc.identifier.urihttps://hdl.handle.net/10037/27673
dc.language.isoengen_US
dc.publisherWileyen_US
dc.relation.journalJournal of Oral Rehabilitation
dc.relation.urihttps://onlinelibrary.wiley.com/doi/epdf/10.1111/joor.13364
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2022 The Author(s)en_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0en_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)en_US
dc.titleMaxillary overdenture on three implants retained by low-profile stud attachments – A prospective cohort studyen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
Med mindre det står noe annet, er denne innførselens lisens beskrevet som Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)