Vis enkel innførsel

dc.contributor.authorTorbjørnsen, Astrid
dc.contributor.authorSmåstuen, Milada C
dc.contributor.authorJenum, Anne Karen
dc.contributor.authorÅrsand, Eirik
dc.contributor.authorRibu, Lis
dc.date.accessioned2019-01-09T13:29:14Z
dc.date.available2019-01-09T13:29:14Z
dc.date.issued2018
dc.description.abstract<p><i>Background</i>: When developing a mobile health app, users’ perception of the technology should preferably be evaluated. However, few standardized and validated questionnaires measuring acceptability are available.</p> <p><i>Objective</i>: The aim of this study was to assess the validity of the Norwegian version of the Service User Technology Acceptability Questionnaire (SUTAQ).</p> <p><i>Methods</i>: Persons with type 2 diabetes randomized to the intervention groups of the RENEWING HEALTH study used a diabetes diary app. At the one-year follow-up, participants in the intervention groups (n=75) completed the self-reported instrument SUTAQ to measure the acceptability of the equipment. We conducted confirmatory factor analysis for evaluating the fit of the original five-factor structure of the SUTAQ.</p> <p><i>Results</i>: We confirmed only 2 of the original 5 factors of the SUTAQ, perceived benefit and care personnel concerns.</p> <p><i>Conclusions</i>: The original five-factor structure of the SUTAQ was not confirmed in the Norwegian study, indicating that more research is needed to tailor the questionnaire to better reflect the Norwegian setting. However, a small sample size prevented us from drawing firm conclusions about the translated questionnaire.</p>en_US
dc.description.sponsorshipNorwegian Research Council EU Health Authorities of Northern Norway The Norwegian Centre for E-health Research Akershus University College of Applied Sciences Akershus University Hospital The Norwegian Diabetes Association.en_US
dc.descriptionSource at <a href=https://doi.org/10.2196/10255> https://doi.org/10.2196/10255</a>.en_US
dc.identifier.citationTorbjørnsen, A., Småstuen, M.C., Jenum, A.K., Årsand, E. & Ribu, L. (2018). The Service User Technology Acceptability Questionnaire: Psychometric Evaluation of the Norwegian Version. <i>JMIR Human Factors</i>, 5(4). https://doi.org/10.2196/10255en_US
dc.identifier.cristinIDFRIDAID 1650141
dc.identifier.doi10.2196/10255
dc.identifier.issn2292-9495
dc.identifier.urihttps://hdl.handle.net/10037/14403
dc.language.isoengen_US
dc.publisherJMIR Publicationsen_US
dc.relation.journalJMIR Human Factors
dc.rights.accessRightsopenAccessen_US
dc.subjectVDP::Medical disciplines: 700::Health sciences: 800en_US
dc.subjectVDP::Medisinske Fag: 700::Helsefag: 800en_US
dc.titleThe Service User Technology Acceptability Questionnaire: Psychometric Evaluation of the Norwegian Versionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel