dc.contributor.author | Skeie, Marit Slåttelid | |
dc.contributor.author | Frid, Paula | |
dc.contributor.author | Mustavfa, Manal | |
dc.contributor.author | Aßmus, Jörg | |
dc.contributor.author | Rosén, Annika | |
dc.date.accessioned | 2019-03-08T10:17:35Z | |
dc.date.available | 2019-03-08T10:17:35Z | |
dc.date.issued | 2018-09-26 | |
dc.description.abstract | <i>Objectives</i>: The objectives of this study were to assess the interexaminer agreement between one “reference” (gold standard) and
each of two examiners, using the DC/TMD examination method, Axis I and to evaluate whether a recalibration changed reliability
values. <p>
<p><i>Methods</i>: Participants (4 healthy and 12 TMD patients) in 2013 underwent a clinical examination according to DC/TMDs,
Axis I. In 2014, additionally 16 participants (4 healthy and 12 TMD patients) were recruited. Two trainee examiners (one more
experienced) and one “reference examiner” (gold standard) at both sessions assessed the participants. Calibration preparation
(2013): ,e clinical protocol was sent to the trainee examiners with a request that its verbal commands should be learned by heart.
An eight-hour-course was provided on the day preceding the examination session day. Recalibration preparation (2014): ,e same
examiners in advance to this year’s examination session were also asked to recapture the protocol’s instructions (verbal commands
to be learned by heart) and go through the information from the 2013 course and encouraged to contact by e-mail in case of
unclear subjects. At a meeting prior to the examination session, they were also given the opportunities to ask questions. ,e
interexaminer agreements in 2013 and 2014 between the “reference” and each examiner were analysed using Bland–Altman plots,
intraclass correlation coefficient, Cohen’s kappa, and consistency values. <p>
<p><i>Results</i>: For the majority of the gathered data, no clear
change of agreement between 2013 and 2014 could be observed, and only one muscle zone in 2014 could show any clear difference
in agreement between the examiners. <p>
<p><i>Conclusions</i>: No clear and consistent difference in the level of agreement between the two
examiners could be observed, although one was more experienced than the other. Likewise, for most components of the DC/TMD
tool, recalibration of examiners did not change the reliability findings. | en_US |
dc.description | Source at <a href=https://doi.org/10.1155/2018/7474608>https://doi.org/10.1155/2018/7474608. </a> | en_US |
dc.identifier.citation | Skeie, M.S., Frid, P., Mustafa, M., Aßmus, J. & Rosén, A. (2018). DC/TMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability. <i>Pain Research & Management</i>, 7474608. https://doi.org/10.1155/2018/7474608 | en_US |
dc.identifier.cristinID | FRIDAID 1642699 | |
dc.identifier.doi | 10.1155/2018/7474608 | |
dc.identifier.issn | 1203-6765 | |
dc.identifier.issn | 1918-1523 | |
dc.identifier.uri | https://hdl.handle.net/10037/14906 | |
dc.language.iso | eng | en_US |
dc.publisher | Hindawi Publishing Corporation | en_US |
dc.relation.journal | Pain Research & Management | |
dc.rights.accessRights | openAccess | en_US |
dc.subject | VDP::Medical disciplines: 700::Basic medical, dental and veterinary science disciplines: 710 | en_US |
dc.subject | VDP::Medisinske Fag: 700::Basale medisinske, odontologiske og veterinærmedisinske fag: 710 | en_US |
dc.title | DC/TMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability | en_US |
dc.type | Journal article | en_US |
dc.type | Tidsskriftartikkel | en_US |
dc.type | Peer reviewed | en_US |