Performance and Design Study of Optimized LNG Mixed Fluid Cascade Processes

Permanent lenke
https://hdl.handle.net/10037/16399
DOI
https://doi.org/10.1016/j.energy.2019.116207
Thumbnail
Åpne
article.pdf (2.614Mb)
Accepted manuscript version (PDF)
Dato
2019-09-26
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Brodal, Eivind; Jackson, Steven; Eiksund, Oddmar
Sammendrag
Mixed Fluid Cascade (MFC) processes are often claimed to be one of the most efficient methods to liquefy natural gas. Their performance depends on both operating conditions such as ambient temperature, and system design parameters such as exchanger sizes. The performance of the standard MFC process can be further improved by modifying the design with additional equipment, such as liquid refrigerant expanders or additional pressure levels in the refrigerant cycles. This article presents a performance study of several modified MFC processes. Results are obtained using multivariable optimization algorithms in MATLAB and a process model developed in HYSYS. Constraints related to minimum internal temperature approach are used to model the main heat exchangers. The results illustrate the impact of ambient temperature on performance, and that modifications with either two-stage pre-cooling systems or liquid expanders reduce the power consumption by 3.0%–4.5%, translating into a 15%–30% reduction in the combined UA values of the main heat exchangers.
Beskrivelse
Accepted manuscript. Final version published in Energy, 189, 116207, is available at https://doi.org/10.1016/j.energy.2019.116207.
Forlag
Elsevier
Sitering
Brodal, E., Jackson, S. & Eiksund, O. (2019). Performance and Design Study of Optimized LNG Mixed Fluid Cascade Processes. Energy, 189, 116207. https://doi.org/10.1016/j.energy.2019.116207
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (automasjon og prosessteknologi) [172]

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring