Vis enkel innførsel

dc.contributor.authorFøreland, Solveig
dc.contributor.authorRobertsen, Øystein
dc.contributor.authorHegseth, Marit Nøst
dc.date.accessioned2019-10-16T12:35:20Z
dc.date.available2019-10-16T12:35:20Z
dc.date.issued2019-06-19
dc.description.abstract<p><i>Background - </i>Respirator fit testing is a method to assess if the respirator provides an adequate face seal for the worker. <p><i>Methods - </i>Workers from four Norwegian smelters were invited to participate in the study, and 701 respirator fit tests were performed on 127 workers. Fourteen respirator models were included: one FFABE1P3 and 11 FFP3 respirator models produced in one size and two silicone half masks with P3 filters available in three sizes. The workers performed a quantitative fit test according to Health and Safety Executive 282/28 with 5–6 different respirator models, and they rated the respirators based on comfort. Predictors of overall fit factors were explored. <p><i>Results - </i>The pass rate for all fit tests was 62%, 56% for women, and 63% for men. The silicone respirators had the highest percentage of passed tests (92–100%). The pass rate for the FFP3 models varied from 19–89%, whereas the FFABE1P3 respirator had a pass rate of 36%. Five workers did not pass with any respirators, and 14 passed with all the respirators tested. Only 63% passed the test with the respirator they normally used. The mean comfort score on the scale from 1 to 5 was 3.2. The respirator model was the strongest predictor of the overall fit factor. The other predictors (age, sex, and comfort score) did not improve the fit of the model. <p><i>Conclusion - </i>There were large differences in how well the different respirator models fitted the Norwegian smelter workers. The results can be useful when choosing which respirators to include in respirator fit testing programs in similar populations.en_US
dc.description.sponsorshipNorwegian Research Council Norwegian Ferroalloy Producers Research Association Washington Mills AS Saint-Gobainen_US
dc.descriptionSource at <a href=https://doi.org/10.1016/j.shaw.2019.06.004>https://doi.org/10.1016/j.shaw.2019.06.004</a>.en_US
dc.identifier.citationFøreland, S., Robertsen, Ø. & Hegseth, M.N. (2019). Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry? <i>Safety and Health at Work, 10</i>(3), 370-376. https://doi.org/10.1016/j.shaw.2019.06.004en_US
dc.identifier.cristinIDFRIDAID 1711748
dc.identifier.doi10.1016/j.shaw.2019.06.004
dc.identifier.issn2093-7911
dc.identifier.issn2093-7997
dc.identifier.urihttps://hdl.handle.net/10037/16417
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.journalSH@W Safety and Health at Work
dc.relation.projectIDinfo:eu-repo/grantAgreement/RCN/NANO2021/245216/Norway/Generation, protection and health effects of nano-sized dust in the ferroalloy industry/DEMASKUS/en_US
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S2093791118304864
dc.rights.accessRightsopenAccessen_US
dc.subjectVDP::Medical disciplines: 700::Health sciences: 800::Company health service: 810en_US
dc.subjectVDP::Medisinske Fag: 700::Helsefag: 800::Bedriftsmedisin: 810en_US
dc.subjectFit factoren_US
dc.subjectPredictors of fiten_US
dc.subjectRespiratory protective equipmenten_US
dc.subjectQuantitative respirator fit testen_US
dc.subjectSmelting industryen_US
dc.titleDo Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?en_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel