Vis enkel innførsel

dc.contributor.authorLópez-Liria, Remedios
dc.contributor.authorLópez-Villegas, Antonio
dc.contributor.authorLeal-Costa, César
dc.contributor.authorPeiró, Salvador
dc.contributor.authorRobles-Musso, Emilio
dc.contributor.authorBautista-Mesa, Rafael
dc.contributor.authorRocamora-Pérez, Patricia
dc.contributor.authorLappegård, Knut Tore
dc.contributor.authorCatalán-Matamoros, Daniel
dc.date.accessioned2020-08-11T11:09:48Z
dc.date.available2020-08-11T11:09:48Z
dc.date.issued2020-02-23
dc.description.abstractHealth-related quality of life (HRQoL) and functional capacity values immediately after pacemaker (PM) implantation have been well established; however, not much has been known about its long-term effects. The present study compared the long-term effectiveness and safety of remote monitoring plus a clinic visit versus clinic visits alone during follow-up of adults implanted with PMs. This study was a single-centre, controlled, non-randomised, non-blinded clinical trial. Data were collected pre-implantation and after 60 months. The patients in the PONIENTE study were assigned to two different groups: remote monitoring (RM) and conventional monitoring (CM). The EuroQol-5D (EQ-5D) questionnaire was used to assess HRQoL and Duke Activity Status Index was used for the functional capacity. After five years, 55 patients completed the study (RM = 21; CM = 34). EuroQol-5D and functional capacity values were improved; however, significant differences were observed only in the EQ5D visual analogue scale (p < 0.001). Remote monitoring was equally feasible, reliable, safe, and clinically useful as CM. The frequencies of rehospitalisations and emergency visits did not differ between the groups. RM was found to be safe and effective in early detection and treatment of medical- and device-related events and in reducing hospital visits. Improved HRQoL was described not only immediately after PM implantation but also extended over a long time.en_US
dc.identifier.citationLópez-Liria, López-Villegas, Leal-Costa, Peiró, Robles-Musso, Bautista-Mesa, Rocamora-Pérez, Lappegård, Catalán-Matamoros. Effectiveness and safety in remote monitoring of patients with pacemakers five years after an implant: The Poniente study. International Journal of Environmental Research and Public Health. 2020;17(4)en_US
dc.identifier.cristinIDFRIDAID 1821677
dc.identifier.doi10.3390/ijerph17041431
dc.identifier.issn1660-4601
dc.identifier.urihttps://hdl.handle.net/10037/18945
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.relation.journalInternational Journal of Environmental Research and Public Health
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2020 The Author(s)en_US
dc.subjectVDP::Medical disciplines: 700en_US
dc.subjectVDP::Medisinske Fag: 700en_US
dc.titleEffectiveness and safety in remote monitoring of patients with pacemakers five years after an implant: The Poniente studyen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel