ub.xmlui.mirage2.page-structure.muninLogoub.xmlui.mirage2.page-structure.openResearchArchiveLogo
    • EnglishEnglish
    • norsknorsk
  • Velg spraaknorsk 
    • EnglishEnglish
    • norsknorsk
  • Administrasjon/UB
Vis innførsel 
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
JavaScript is disabled for your browser. Some features of this site may not work without it.

A modified clot-based assay to measure negatively charged procoagulant phospholipids

Permanent lenke
https://hdl.handle.net/10037/22379
DOI
https://doi.org/10.1038/s41598-021-88835-y
Thumbnail
Åpne
article.pdf (1.508Mb)
Publisert versjon (PDF)
Dato
2021-04-29
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Ramberg, Cathrine; Jamaly, Simin; Latysheva, Nadezhda; Wilsgård, line; Sovershaev, Timofey; Snir, Omri; Hansen, Jesper
Sammendrag
Growing evidence supports a role for extracellular vesicles (EVs) in haemostasis and thrombosis due to exposure of negatively charged procoagulant phospholipids (PPL). Current commercial PPL-dependent clotting assays use chemically phospholipid depleted plasma to measure PPL activity. The purpose of our study was to modify the PPL assay by substituting the chemically phospholipid depleted plasma with PPL depleted plasma obtained by ultracentrifugation This in order to get readily access to a sensitive and reliable assay to measure PPL activity in human plasma and cell supernatants. The performance of the assay was tested, including the influence of individual coagulation factors and postprandial lipoproteins and compared to a commercial PPL assay (STA-Procoag-PPL). The two PPL assays displayed similar sensitivity to exogenously added standardized phospholipids. The PPL activity measured by the modified assay strongly correlates with the results from the commercial assay. The intraday- and between-days coefficients of variation ranged from 2–4% depending on the PPL activity in the sample. The modified PPL assay was insensitive to postprandial lipoprotein levels in plasma, as well as to tissue factor (TF) positive EVs from stimulated whole blood. Our findings showed that the modified assay performed equal to the comparator, and was insensitive to postprandial lipoproteins and TF+ EVs.
Er en del av
Ramberg, C. (2021). The Role of Plasma Extracellular Vesicles and Procoagulant Phospholipid Activity in Venous Thromboembolism. (Doctoral thesis). https://hdl.handle.net/10037/22767.
Forlag
Nature Research
Sitering
Ramberg, Jamaly, Latysheva, Wilsgård, Sovershaev, Snir, Hansen. A modified clot-based assay to measure negatively charged procoagulant phospholipids. Scientific Reports. 2021;11
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (klinisk medisin) [1974]
Copyright 2021 The Author(s)

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring