ub.xmlui.mirage2.page-structure.muninLogoub.xmlui.mirage2.page-structure.openResearchArchiveLogo
    • EnglishEnglish
    • norsknorsk
  • Velg spraaknorsk 
    • EnglishEnglish
    • norsknorsk
  • Administrasjon/UB
Vis innførsel 
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
JavaScript is disabled for your browser. Some features of this site may not work without it.

New clinical data on human spinal cord re-irradiation tolerance

Permanent lenke
https://hdl.handle.net/10037/22826
DOI
https://doi.org/10.1007/s00066-021-01772-7
Thumbnail
Åpne
article.pdf (245.4Kb)
Publisert versjon (PDF)
Dato
2021-05-05
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Doi, Hiroshi; Tamari, Keisuke; Oh, Ryoong-Jin; Nieder, Carsten
Sammendrag
Purpose - To provide additional clinical data about the re-irradiation tolerance of the spinal cord.

Methods - This was a retrospective bi-institutional study of patients re-irradiated to the cervical or thoracic spinal cord with minimum follow-up of 6 months. The maximum dose (Dmax) and dose to 0.1cc (D0.1cc) were determined (magnetic resonance imaging [MRI]-defined cord) and expressed as equivalent dose in 2‑Gy fractions (EQD2) with an α/β value of 2 Gy.

Results - All 32 patients remained free from radiation myelopathy after a median follow-up of 12 months. Re-irradiation was performed after 6–97 months (median 15). In 22 cases (69%) the re-irradiation spinal cord EQD2 Dmax was higher than that of the first treatment course. Forty-eight of 64 treatment courses employed fraction sizes of 2.5 to 4 Gy to the target volume. The median cumulative spinal cord EQD2 Dmax was 80.7 Gy, minimum 61.12 Gy, maximum 114.79 Gy. The median cumulative spinal cord D0.1cc EQD2 was 76.1 Gy, minimum 61.12 Gy, maximum 95.62 Gy. Besides cumulative dose, other risk factors for myelopathy were present (single-course Dmax EQD2 ≥51 Gy in 9 patients, single-course D0.1cc EQD2 ≥51 Gy in 5 patients).

Conclusion - Even patients treated to higher cumulative doses than previously recommended, or at a considerable risk of myelopathy according to a published risk score, remained free from this complication, although one must acknowledge the potential for manifestation of damage in patients currently alive, i.e., still at risk. Individualized decisions to re-irradiate after appropriate informed consent are an acceptable strategy, including scenarios where low re-irradiation doses to the spinal cord would compromise target coverage and tumor control probability to an unacceptable degree.
Forlag
Springer
Sitering
Doi, Tamari, Oh, Nieder. New clinical data on human spinal cord re-irradiation tolerance. Strahlentherapie und Onkologie (Print). 2021;197:463-473
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (klinisk medisin) [1974]
Copyright 2021 The Author(s)

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring