A hands-free carotid Doppler can identify spontaneous circulation without interrupting cardiopulmonary resuscitation: an animal study
Permanent lenke
https://hdl.handle.net/10037/36098Dato
2024-12-27Type
Journal articleTidsskriftartikkel
Peer reviewed
Forfatter
Faldaas, Bjørn Ove; Storm, Benjamin Stage; Lappegård, Knut Tore; How, Ole-Jakob; Nilsen, Bent Aksel; Kiss, Gabriel Hanssen; Skogvoll, Eirik; Nielsen, Erik Waage; Torp, Hans; Ingul, Charlotte Ingeborg BjörkSammendrag
Background Identifying spontaneous circulation during cardiopulmonary resuscitation (CPR) is challenging. Current methods, which involve intermittent and time-consuming pulse checks, necessitate pauses in chest compressions. This issue is problematic in both in-hospital cardiac arrest and out-of-hospital cardiac arrest situations, where resources for identifying circulation during CPR may be limited. The fraction of chest compression plays a pivotal role in improving survival rates. To address this challenge, we evaluated a newly developed hands-free, continuous carotid Doppler system (RescueDoppler), designed to identify spontaneous circulation during chest compressions. In our study, we utilized a porcine model of cardiac arrest to investigate sequences of ventricular fbrillation, followed by defibrillation, and monitoring for the return of spontaneous circulation during chest compressions with the carotid Doppler system. We explored both manual compressions at 100 and 50 compressions per minute and mechanical compressions. To estimate the detection rate (i.e., sensitivity), we employed a logistic mixed model with animal identity as random effect.
Results Offline analysis of Doppler color M-mode and spectral display successfully identified spontaneous circulation during chest compressions in all compression models. Spontaneous circulation was detected in 51 of 59 sequences, yielding an expected sensitivity of 98% with a 95% confidence interval of 59% to 99%.
Conclusion The RescueDoppler, a continuous hands-free carotid Doppler system, demonstrates an expected sensitivity of 98% for identifying spontaneous circulation during both manual and mechanical chest compressions. Clinical studies are needed to further validate these findings.