Vis enkel innførsel

dc.contributor.authorHaug, Bjørn
dc.contributor.authorKjelsberg, Kjærsti
dc.contributor.authorLappegård, Knut Tore
dc.date.accessioned2012-04-18T09:17:38Z
dc.date.available2012-04-18T09:17:38Z
dc.date.issued2011
dc.description.abstractSome countries have a demography that makes it necessary to maintain relatively small pacemaker centres. We wanted to assess the quality of pacemaker surgery in two such hospitals. Through patient records we gathered information on ∼535 consecutive primary pacemaker implantations in two small pacemaker centres with 30 and 80 annual operations, respectively. All patients were followed for 3 years. All complications documented in the patient records were registered. Furthermore, we performed a non-systematic literature search comparing our data with reports from major centres published over the last 10 years.We found 72 complications in 64 (12.0%) of the patients, the most common being bleeding, lead failure, and pneumothorax. If minor bleedings without any consequences for the patients are excluded, the number of complications was 46 in 40 patients (7.5%). We had to reoperate on 5.2% of the patients. There was no statistically significant difference in complication rates between the two hospitals. Education candidates generated statistically significant more complications than experienced doctors (13.7 vs. 7.1%, P < 0.05). There are no generally accepted norms of complication rates in pacemaker surgery. However, we found no indications that our centres have a rate of complications that is unacceptably high.en
dc.identifier.citationEuropace 13(2011) nr. 11 s. 1580-1586en
dc.identifier.cristinIDFRIDAID 869255
dc.identifier.doidoi: 10.1093/europace/eur162
dc.identifier.issn1099-5129
dc.identifier.urihttps://hdl.handle.net/10037/4110
dc.identifier.urnURN:NBN:no-uit_munin_3830
dc.language.isoengen
dc.publisherOxford Journalsen
dc.rights.accessRightsopenAccess
dc.subjectVDP::Medical disciplines: 700::Clinical medical disciplines: 750::Cardiology: 771en
dc.subjectVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Kardiologi: 771en
dc.subjectVDP::Medical disciplines: 700::Clinical medical disciplines: 750::Vascular and thoracic surgery: 782en
dc.subjectVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Kar- og thoraxkirurgi: 782en
dc.titlePacemaker implantation in small hospitals : complication rates comparable to larger centresen
dc.typeJournal articleen
dc.typeTidsskriftartikkelen
dc.typePeer revieweden


Tilhørende fil(er)

Thumbnail
Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel