Arm Crank and Wheelchair Ergometry Produce Similar Peak Oxygen Uptake but Different Work Economy Values in Individuals with Spinal Cord Injury

Permanent lenke
https://hdl.handle.net/10037/9646
DOI
https://doi.org/10.1155/2016/5481843
Thumbnail
Åpne
article.pdf (1.917Mb)
Publisher's version (PDF)
Dato
2016-03-20
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Tørhaug, Tom; Brurok, Berit; Hoff, Jan; Helgerud, Jan; Leivseth, Gunnar
Sammendrag
Objective. To study whether values for peak oxygen uptake (VO2peak) and work economy (WE) at a standardized workload are different when tested by arm crank ergometry (ACE) and wheelchair ergometry (WCE). Methods. Twelve paraplegic men with spinal cord injury (SCI) in stable neurological condition participated in this cross-sectional repeated-measures study. We determined VO2peak and peak power output (POpeak) values during ACE and WCE in a work-matched protocol. Work economy was tested at a standardized workload of 30 Watts (W) for both ACE and WCE. Results. There were no significant differences in VO2peak (mL·kg−1·min−1) between ACE (27.3 +/- 3.2) and WCE (27.4 +/- 3.8) trials, and a Bland-Altman plot shows that findings are within 95% level of agreement. WE or oxygen consumption at 30 W (VO2-30W) was significantly lower during WCE compared to ACE (P < 0.039). Mean (95% CI) POpeak (W) were 130 (111–138) and 100 (83–110) during ACE and WCE, respectively. Conclusion. The findings in the present study support the use of both ACE and WCE for testing peak oxygen uptake. However, WE differed between the two test modalities, meaning that less total energy is used to perform external work of 30 W during wheelchair exercise when using this WCE (VP100 Handisport ergometer). Clinical Trials Protocol Record is NCT00987155/4.2007.2271.
Beskrivelse
Publisher's version, source: http://dx.doi.org/10.1155/2016/5481843.
Forlag
Hindawi Publishing Corporation
Sitering
BioMed Research International, Volume 2016, Article ID 5481843, 7 pages
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (klinisk medisin) [1974]

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring