ub.xmlui.mirage2.page-structure.muninLogoub.xmlui.mirage2.page-structure.openResearchArchiveLogo
    • EnglishEnglish
    • norsknorsk
  • Velg spraakEnglish 
    • EnglishEnglish
    • norsknorsk
  • Administration/UB
View Item 
  •   Home
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • View Item
  •   Home
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Static and functional hemodynamic profiles of women with abnormal uterine artery doppler at 22-24 weeks of gestation

Permanent link
https://hdl.handle.net/10037/10721
DOI
https://doi.org/10.1371/journal.pone.0157916
Thumbnail
View/Open
article.pdf (276.6Kb)
publisher's pdf (PDF)
Date
2016
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Vårtun, Åse; Flo, Kari; Widnes, Christian; Acharya, Ganesh
Abstract
Objective To compare cardiac function, systemic hemodynamics and preload reserve of women with increased (cases) and normal (controls) uterine artery (UtA) pulsatility index (PI) at 22–24 weeks of gestation. Materials and Methods A prospective cross-sectional study of 620 pregnant women. UtA blood flow velocities were measured using Doppler ultrasonography, and PI was calculated. Mean UtA PI ≥ 1.16 (90th percentile) was considered abnormal. Maternal hemodynamics was investigated at baseline and during passive leg raising (PLR) using impedance cardiography (ICG). Preload reserve was defined as percent increase in stroke volume (SV) 90 seconds after passive leg raising compared to baseline. Results Mean UtA PI was 1.49 among cases (n = 63) and 0.76 among controls (n = 557) (p < 0.0001). Eighteen (28.6%) cases and 53 (9.5%) controls developed pregnancy complications (p <0.0001). The mean arterial pressure and systemic vascular resistance were 83 mmHg and 1098.89±293.87 dyne s/cm5 among cases and 79 mmHg and 1023.95±213.83 dyne s/cm5 among controls (p = 0.007 and p = 0.012, respectively). Heart rate, SV and cardiac output were not different between the groups. Both cases and controls responded with a small (4–5%) increase in SV in response to PLR, but the cardiac output remained unchanged. The preload reserve was not significantly different between two groups. Conclusion Pregnant women with abnormal UtA PI had higher blood pressure and systemic vascular resistance, but similar functional hemodynamic profile at 22–24 weeks compared to controls. Further studies are needed to clarify whether functional hemodynamic assessment using ICG can be useful in predicting pregnancy complications.
Description
Published version. Source at http://doi.org/10.1371/journal.pone.0157916. License CC BY 4.0.
Publisher
Public Library of Science
Citation
Vårtun Å, Flo K, Widnes C, Acharya G. Static and functional hemodynamic profiles of women with abnormal uterine artery doppler at 22-24 weeks of gestation. PLoS ONE. 2016;11:e0157916(6)
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (klinisk medisin) [1974]

Browse

Browse all of MuninCommunities & CollectionsAuthor listTitlesBy Issue DateBrowse this CollectionAuthor listTitlesBy Issue Date
Login

Statistics

View Usage Statistics
UiT

Munin is powered by DSpace

UiT The Arctic University of Norway
The University Library
uit.no/ub - munin@ub.uit.no

Accessibility statement (Norwegian only)