Vis enkel innførsel

dc.contributor.authorCaglayan, Hatice Akay
dc.contributor.authorKjønås, Didrik
dc.contributor.authorMalm, Siri
dc.contributor.authorSchirmer, Henrik
dc.contributor.authorRøsner, Assami
dc.date.accessioned2021-10-19T10:59:28Z
dc.date.available2021-10-19T10:59:28Z
dc.date.issued2021-09-28
dc.description.abstractBackground - The 2016 guidelines of the American Society of Echocardiography (ASE) and European Association of Cardiovascular Imaging (EACVI) for evaluation of left ventricular (LV) diastolic dysfunction by Doppler flow and tissue Doppler- echocardiography do not adjust assessment of high filling pressures for patients with aortic stenosis (AS). However, most of the studies on this patient group indicate age independent specific diastolic features in AS. The aim of this study is to identify disease-specific range and distribution of diastolic functional parameters and their ability to identify high N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels as a marker for high filling pressures.<p> <p>Methods - In this study, 169 patients who underwent surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) were prospectively enrolled. Resting echocardiography was performed including Doppler of the mitral inflow, pulmonary venous flow, tricuspid regurgitant flow and tissue Doppler in the mitral ring and indexed volume-estimates of the left atrium (LAVI). Echocardiography, and NT-proBNP levels were assessed before TAVR/SAVR and at two postoperative visits at 6 and 12 months.<p> <p>Results - Pre- and postoperative values were septal e′; 5.1 ± 3.9, 5.2 ± 1.6 cm/s; lateral e′ 6.3 ± 2.1; 7.7 ± 2.7 cm/s; E/e′19 ± 8; 16 ± 7 cm/s; E velocity 96 ± 32; 95 ± 32 cm/s; LAVI 39 ± 8; 36 ± 8 ml/m2, pulmonary artery pressure (PAP) 39 ± 8; 36 ± 8 mmHg, respectively. The scoring recommended by ASE/EACVI detected elevated NT pro-BNP with a specificity of 25%. Adjusting thresholds towards PAP ≥ 40 mmHg, E velocity ≥ 100 cm/s, E deceleration time < 220 ms, and E/septal e′ ≥ 20 or septal e′ < 5.0 cm/s increased prediction of NT-proBNP levels ≥500 ng/L with substantially improved specificity (> 85%).<p> <p>Conclusion - Diastolic echocardiographic parameters in AS indicate persistent impaired relaxation and NT-proBNP indicate elevated filling pressures in most of the patients, improving only modestly 6–12 months after TAVR and SAVR. Applying the 2016 ASE/EACVI recommendations for detection of elevated filling pressures to patients with AS, elevated NT pro-BNP levels could not be reliably detected. However, adjusting thresholds of the echocardiographic parameters increased specificities to useful diagnostic levels.en_US
dc.identifier.citationCaglayan, Kjønås, Malm, Schirmer, Røsner. Echocardiographic assessment of diastolic dysfunction in elderly patients with severe aortic stenosis before and after aortic valve replacement. Cardiovascular Ultrasound. 2021;19:32:1-14en_US
dc.identifier.cristinIDFRIDAID 1944141
dc.identifier.doi10.1186/s12947-021-00262-1
dc.identifier.issn1476-7120
dc.identifier.urihttps://hdl.handle.net/10037/22785
dc.language.isoengen_US
dc.publisherBMCen_US
dc.relation.journalCardiovascular Ultrasound
dc.rights.accessRightsopenAccessen_US
dc.rights.holderCopyright 2021 The Author(s)en_US
dc.subjectVDP::Medical disciplines: 700::Basic medical, dental and veterinary science disciplines: 710en_US
dc.subjectVDP::Medisinske Fag: 700::Basale medisinske, odontologiske og veterinærmedisinske fag: 710en_US
dc.titleEchocardiographic assessment of diastolic dysfunction in elderly patients with severe aortic stenosis before and after aortic valve replacementen_US
dc.type.versionpublishedVersionen_US
dc.typeJournal articleen_US
dc.typeTidsskriftartikkelen_US
dc.typePeer revieweden_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel