ub.xmlui.mirage2.page-structure.muninLogoub.xmlui.mirage2.page-structure.openResearchArchiveLogo
    • EnglishEnglish
    • norsknorsk
  • Velg spraakEnglish 
    • EnglishEnglish
    • norsknorsk
  • Administration/UB
View Item 
  •   Home
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • View Item
  •   Home
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Retinal vascular calibre and response to light exposure and serial imaging

Permanent link
https://hdl.handle.net/10037/25486
DOI
https://doi.org/10.1111/aos.12213
Thumbnail
View/Open
article.pdf (299.5Kb)
Published version (PDF)
Date
2013-07-04
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Author
Hanno, Therese von; Sjølie, Anne Katrin; Mathiesen, Ellisiv B.
Abstract
Purpose: To investigate whether retinal vessel calibre measurements on optical retinal photography are affected by light and dark exposure prior to photography and whether the vessel calibre changes during an imaging sequence of several images.

Methods: Digital optical retinal photographs were obtained from 32 healthy adults in two separate image sequences of six images during 1 min; one sequence with 10 min of dark exposure and one with 10 min of light exposure prior to imaging. Retinal arteriolar and venular calibres were measured computer-assisted and summarized as central retinal artery and vein equivalents (CRAE and CRVE). Outcome measures were difference in calibres after prior light versus prior dark exposure and difference in calibre during each of the two imaging sequences.

Results: CRVE was wider with prior light exposure (2.7%, p = 0.0001), comparing the first image in each image sequence. Within each sequence, there was a venular dilatation from first to last image, both with prior light exposure (1.7%, p = 0.0003) and prior dark exposure (3.1%, p < 0.0001), with the change less pronounced with prior light exposure (p = 0.0164). CRAE showed no significant change in either outcome.

Conclusions: Retinal venular calibre was wider with light exposure prior to imaging and increased slightly during the imaging sequences, less pronounced after prior light than dark exposure. Measurement error due to these effects will probably be reduced by avoiding dark prior to imaging, and a possible bias effect of endothelial dysfunction may possibly be reduced by measuring calibre on an image taken early in the image sequence.

Publisher
Wiley
Citation
Hanno T, Sjølie AK, Mathiesen EB. Retinal vascular calibre and response to light exposure and serial imaging. Acta Ophthalmologica. 2014;92(5):444-448
Metadata
Show full item record
Collections
  • Artikler, rapporter og annet (klinisk medisin) [1974]
Copyright 2013 The Author(s)