Retinal vascular calibre and response to light exposure and serial imaging
Permanent link
https://hdl.handle.net/10037/25486Date
2013-07-04Type
Journal articleTidsskriftartikkel
Peer reviewed
Abstract
Methods: Digital optical retinal photographs were obtained from 32 healthy adults in two separate image sequences of six images during 1 min; one sequence with 10 min of dark exposure and one with 10 min of light exposure prior to imaging. Retinal arteriolar and venular calibres were measured computer-assisted and summarized as central retinal artery and vein equivalents (CRAE and CRVE). Outcome measures were difference in calibres after prior light versus prior dark exposure and difference in calibre during each of the two imaging sequences.
Results: CRVE was wider with prior light exposure (2.7%, p = 0.0001), comparing the first image in each image sequence. Within each sequence, there was a venular dilatation from first to last image, both with prior light exposure (1.7%, p = 0.0003) and prior dark exposure (3.1%, p < 0.0001), with the change less pronounced with prior light exposure (p = 0.0164). CRAE showed no significant change in either outcome.
Conclusions: Retinal venular calibre was wider with light exposure prior to imaging and increased slightly during the imaging sequences, less pronounced after prior light than dark exposure. Measurement error due to these effects will probably be reduced by avoiding dark prior to imaging, and a possible bias effect of endothelial dysfunction may possibly be reduced by measuring calibre on an image taken early in the image sequence.