ub.xmlui.mirage2.page-structure.muninLogoub.xmlui.mirage2.page-structure.openResearchArchiveLogo
    • EnglishEnglish
    • norsknorsk
  • Velg spraaknorsk 
    • EnglishEnglish
    • norsknorsk
  • Administrasjon/UB
Vis innførsel 
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
  •   Hjem
  • Det helsevitenskapelige fakultet
  • Institutt for klinisk medisin
  • Artikler, rapporter og annet (klinisk medisin)
  • Vis innførsel
JavaScript is disabled for your browser. Some features of this site may not work without it.

Transfer of triptans into human breast milk and estimation of infant drug exposure through breastfeeding

Permanent lenke
https://hdl.handle.net/10037/22210
DOI
https://doi.org/10.1111/bcpt.13579
Thumbnail
Åpne
article.pdf (268.7Kb)
Publisert versjon (PDF)
Dato
2021-03-17
Type
Journal article
Tidsskriftartikkel
Peer reviewed

Forfatter
Amundsen, Siri; Nordeng, Hedvig; Nordeng, Hedvig Marie Egeland; Fuskevåg, Ole Martin; Nordmo, Elisabet; Nordmo, Elisabet N; Sager, Georg; Spigset, Olav
Sammendrag
Clinical data on the transfer of triptans into human breast milk remain scarce. In a lactation study including 19 breastfeeding women with migraine, we examined the excretion of six different triptans into milk. Following intake of a single dose, each participant collected seven breast milk samples at predefined intervals up to 24 hours after dose. Triptan concentrations in milk were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Infant drug exposure was estimated by calculating the relative infant dose (RID). Twenty-two breast milk sample sets were obtained for sumatriptan (n = 8), rizatriptan (n = 5), zolmitriptan (n = 4), eletriptan (n = 3), almotriptan (n = 1) and naratriptan (n = 1). Based on the average concentration in milk throughout the day, estimated mean RIDs (with range in parenthesis) were as follows: eletriptan 0.6% (0.3%-0.8%), sumatriptan 0.7% (0.2%-1.8%), rizatriptan 0.9% (0.3%-1.4%), almotriptan 1.8% (-), zolmitriptan 2.1% (0.7%-5.3%) and naratriptan 5.0% (-). Infant drug exposure through breastfeeding appears to be low and indicates that use of the triptans in this study is compatible with breastfeeding. Naratriptan may not be first choice in breastfeeding mothers initiating triptans during the neonatal period.
Forlag
Wiley
Sitering
Amundsen S, Nordeng, Nordeng HME, Fuskevåg O, Nordmo, Nordmo En, Sager gs, Spigset O. Transfer of triptans into human breast milk and estimation of infant drug exposure through breastfeeding. Basic & Clinical Pharmacology & Toxicology. 2021;128(6):1-10
Metadata
Vis full innførsel
Samlinger
  • Artikler, rapporter og annet (klinisk medisin) [1974]
Copyright 2021 The Author(s)

Bla

Bla i hele MuninEnheter og samlingerForfatterlisteTittelDatoBla i denne samlingenForfatterlisteTittelDato
Logg inn

Statistikk

Antall visninger
UiT

Munin bygger på DSpace

UiT Norges Arktiske Universitet
Universitetsbiblioteket
uit.no/ub - munin@ub.uit.no

Tilgjengelighetserklæring