ST waveform analysis vs. cardiotocography alone for intrapartum fetal monitoring: A systematic review and meta-analysis of randomized trials
Permanent link
https://hdl.handle.net/10037/8504Date
2015Type
Journal articleTidsskriftartikkel
Peer reviewed
Abstract
Key message:
ST waveform analysis is purposed to be better for labor surveillance than conventional CTG.
We quantified the efficacy of these two methods, assessing quality of the scientific evidence
with the GRADE tool, and determined that evidence is insufficient to justify the use of ST
waveform analysis as intrapartum monitoring.
Description